Line 247: Line 247:
  
 The ''portset'' command activates a certain port (for example, //portset(3)// will activate output #3), while the ''portclr'' command clears the specified port (//portclr(3)// will turn off output #3). In order to disable these commands, either delete them from the relevant Software PLCs, or comment them out by putting two forward slashes in front of the commands. Don't forget to press the Save All and Build All buttons to make sure that the changes take effect.  The ''portset'' command activates a certain port (for example, //portset(3)// will activate output #3), while the ''portclr'' command clears the specified port (//portclr(3)// will turn off output #3). In order to disable these commands, either delete them from the relevant Software PLCs, or comment them out by putting two forward slashes in front of the commands. Don't forget to press the Save All and Build All buttons to make sure that the changes take effect. 
 +
 +++++
 +
 +++++ Why is the tool change macro M6 not working? |
 +
 +Check that the M6TXX tool change commands are accepted by the myCNC software (Settings > Config > G-codes settings > Tool Change M6TXX):
 +
 +{{::config-080-tool-change.png}}
  
 ++++ ++++