mycnc:global_variables
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
mycnc:global_variables [2018/10/04 11:54] – skirillov | mycnc:global_variables [2019/04/04 11:45] – skirillov | ||
---|---|---|---|
Line 355: | Line 355: | ||
^ ^^^ | ^ ^^^ | ||
| GVAR_KNIFE_FLAG | 7587 | PLC/ | | GVAR_KNIFE_FLAG | 7587 | PLC/ | ||
+ | ^ Cutchart variables ^^^ | ||
+ | | GVAR_CUTPROCESS_ID | 7600 | | | ||
+ | | GVAR_CUTPROCESS_KERF | 7601 | | | ||
+ | | GVAR_CUTPROCESS_MATERIAL_THICKNESS | 7602 | | | ||
+ | | GVAR_CUTPROCESS_TIME_PREHEAT | 7603 | | | ||
+ | | GVAR_CUTPROCESS_TIME_SOFT_OXY_START | 7604 | | | ||
+ | | GVAR_CUTPROCESS_CUTSPEED | 7605 | | | ||
+ | ^ Oxy Fuel cutting, Automatic Gas Console ^^^ | ||
+ | | GVAR_CUTPROCESS_AGC_IGNITION_FUEL | 7610 | | | ||
+ | | GVAR_CUTPROCESS_AGC_IGNITION_OXY_HEAT | 7611 | | | ||
+ | | GVAR_CUTPROCESS_AGC_PREHEAT_FUEL | 7612 | | | ||
+ | | GVAR_CUTPROCESS_AGC_PIERCE_FUEL | 7613 | | | ||
+ | | GVAR_CUTPROCESS_AGC_PIERCE_OXY_CUT | 7614 | | | ||
+ | | GVAR_CUTPROCESS_AGC_PIERCE_OXY_HEAT | 7615 | | | ||
+ | | GVAR_CUTPROCESS_AGC_CUTTING_FUEL | 7616 | | | ||
+ | | GVAR_CUTPROCESS_AGC_CUTTING_OXY_HEAT | 7617 | | | ||
+ | | GVAR_CUTPROCESS_AGC_CUTTING_OXY_CUT | 7618 | | | ||
+ | | GVAR_CUTPROCESS_AGC_PILOT_FUEL | 7619 | | | ||
+ | | GVAR_CUTPROCESS_AGC_PILOT_OXY_HEAT | 7620 | | | ||
+ | ^ ^^^ | ||
+ | | GVAR_CUTPROCESS_GAS_SELECT1 | 7621 | | | ||
+ | | GVAR_CUTPROCESS_GAS_SELECT2 | 7622 | | | ||
+ | ^ Plasma Cutting, Torch consumables ^^^ | ||
+ | | GVAR_CUTPROCESS_SHIELD_RETAINING_CAP | 7630 | | | ||
+ | | GVAR_CUTPROCESS_SHIELD | 7631 | | | ||
+ | | GVAR_CUTPROCESS_NOZZLE_RETAINING_CAP | 7632 | | | ||
+ | | GVAR_CUTPROCESS_NOZZLE | 7633 | | | ||
+ | | GVAR_CUTPROCESS_SWIRL_RING | 7634 | | | ||
+ | | GVAR_CUTPROCESS_ELECTRODE | 7635 | | | ||
+ | | GVAR_CUTPROCESS_WATER_TUBE | 7636 | | | ||
+ | ^ Plasma Cutting, Height control settings ^^^ | ||
+ | | GVAR_CUTPROCESS_HC_PIERCE_DELAY | 7640 | | | ||
+ | | GVAR_CUTPROCESS_HC_IGNITION_HEIGHT | 7641 | | | ||
+ | | GVAR_CUTPROCESS_HC_PIERCE_HEIGHT | 7642 | | | ||
+ | | GVAR_CUTPROCESS_HC_CUT_HEIGHT | 7643 | | | ||
+ | | GVAR_CUTPROCESS_HC_CONTROL_DELAY | 7644 | | | ||
+ | | GVAR_CUTPROCESS_HC_ARC_VOLTAGE | 7645 | | | ||
+ | | GVAR_CUTPROCESS_HC_PIERCE_HEIGHT_FACTOR | 7646 | | | ||
+ | | GVAR_CUTPROCESS_CREEP_TIME | 7650 | | | ||
+ | | GVAR_CUTPROCESS_CREEP_SPEED | 7651 | | | ||
+ | ^ ^^^ | ||
+ | | GVAR_CUTPROCESS_MIX_GAS1 | 7652 | | | ||
+ | | GVAR_CUTPROCESS_MIX_GAS2 | 7653 | | | ||
+ | ^ Plasma Cutting, Automatic Gas Console ^^^ | ||
+ | | GVAR_CUTPROCESS_AGC_PLASMA_PREFLOW | 7660 | | | ||
+ | | GVAR_CUTPROCESS_AGC_SHIELD_PREFLOW | 7661 | | | ||
+ | | GVAR_CUTPROCESS_AGC_PLASMA_CUTEFLOW | 7662 | | | ||
+ | | GVAR_CUTPROCESS_AGC_SHIELD_CUTEFLOW | 7663 | | | ||
+ | ^ Plasma Cutting, Manual Gas Console ^^^ | ||
+ | | GVAR_CUTPROCESS_MGC_PLASMA_PREFLOW | 7670 | | | ||
+ | | GVAR_CUTPROCESS_MGC_SHIELD_PREFLOW | 7671 | | | ||
+ | | GVAR_CUTPROCESS_MGC_PLASMA_CUTEFLOW | 7672 | | | ||
+ | | GVAR_CUTPROCESS_MGC_SHIELD_CUTEFLOW | 7673 | | | ||
+ | ^ Plasma Cutting ^^^ | ||
+ | | GVAR_CUTPROCESS_SET_PROCESS_CURRENT | 7675 | | | ||
+ | | GVAR_CUTPROCESS_SET_ARC_CURRENT | 7676 | | | ||
+ | | GVAR_CUTPROCESS_CORNER_REDUCTION | 7677 | | | ||
+ | | GVAR_CUTPROCESS_TORCH_TYPE | 7680 | | | ||
+ | | GVAR_CUTPROCESS_MATERIAL_TYPE | 7681 | | | ||
+ | | GVAR_CUTPROCESS_SPECIFIC_MATERIAL | 7682 | | | ||
+ | | GVAR_CUTPROCESS_PLASMA_SHIELD_GASES | 7683 | | | ||
+ | | GVAR_CUTPROCESS_PROCESS | 7684 | | | ||
+ | | GVAR_CUTPROCESS_VENDOR | 7685 | | | ||
+ | | GVAR_CUTPROCESS_TECHNOLOGY | 7686 | | | ||
+ | | GVAR_CUTPROCESS_REVISION | 7687 | | | ||
+ | ^ Encoders ^^^ | ||
| GVAR_ET5_ENCODER | 9000 | (+16) Registers represent Encoder values. Writing to this registers does not affect anything. Selected channel Current Encoder value will be returned when reading these registers. \\ Reading these registers from the controller Hardware PLC will return actual Encoder value. \\ Encoder values in the software are updated about every 128ms. This delay should be counted when using Encoder values from the Software PLC. \\ 9000 - Encoder #0 value \\ 9001 - Encoder #1 value \\ 9002 - Encoder #2 value \\ 9003 - Encoder #3 value \\ 9004 - Encoder #4 value \\ 9005 - Encoder #5 value \\ 9006 - Encoder #6 value \\ 9007 - Encoder #7 value | | | GVAR_ET5_ENCODER | 9000 | (+16) Registers represent Encoder values. Writing to this registers does not affect anything. Selected channel Current Encoder value will be returned when reading these registers. \\ Reading these registers from the controller Hardware PLC will return actual Encoder value. \\ Encoder values in the software are updated about every 128ms. This delay should be counted when using Encoder values from the Software PLC. \\ 9000 - Encoder #0 value \\ 9001 - Encoder #1 value \\ 9002 - Encoder #2 value \\ 9003 - Encoder #3 value \\ 9004 - Encoder #4 value \\ 9005 - Encoder #5 value \\ 9006 - Encoder #6 value \\ 9007 - Encoder #7 value | | ||
| GVAR_ET5_EXPOSITION | 9016 | (+16) Registers represent Motor PID Following Error (a difference between commanded and sensed position). Writing to this registers does not affect anything. A Following Error of Selected PID will be returned when reading these registers. \\ Reading these registers from the controller Hardware PLC will return actual value of the Following Error. \\ Following Error values in the software are updated about every 128ms. This delay should be counted when using the registers in the Software PLC. \\ 9016 - Motor channel #0 PID Following Error \\ 9017 - Motor channel #1 PID Following Error \\ 9018 - Motor channel #2 PID Following Error \\ 9019 - Motor channel #3 PID Following Error \\ 9020 - Motor channel #4 PID Following Error \\ 9021 - Motor channel #5 PID Following Error \\ 9022 - Motor channel #6 PID Following Error \\ 9023 - Motor channel #7 PID Following Error \\ \\ Examples \\ [[plc: | | GVAR_ET5_EXPOSITION | 9016 | (+16) Registers represent Motor PID Following Error (a difference between commanded and sensed position). Writing to this registers does not affect anything. A Following Error of Selected PID will be returned when reading these registers. \\ Reading these registers from the controller Hardware PLC will return actual value of the Following Error. \\ Following Error values in the software are updated about every 128ms. This delay should be counted when using the registers in the Software PLC. \\ 9016 - Motor channel #0 PID Following Error \\ 9017 - Motor channel #1 PID Following Error \\ 9018 - Motor channel #2 PID Following Error \\ 9019 - Motor channel #3 PID Following Error \\ 9020 - Motor channel #4 PID Following Error \\ 9021 - Motor channel #5 PID Following Error \\ 9022 - Motor channel #6 PID Following Error \\ 9023 - Motor channel #7 PID Following Error \\ \\ Examples \\ [[plc: |
mycnc/global_variables.txt · Last modified: 2024/03/20 12:01 by ivan