User Tools

Site Tools


mycnc:independent_pulse_generator

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
mycnc:independent_pulse_generator [2019/10/04 09:36] ivanmycnc:independent_pulse_generator [2020/02/20 08:58] ivan
Line 6: Line 6:
 <code> <code>
 Independent Pulse Generator was added to firmware dated July 20, 2018. Independent Pulse Generator was added to firmware dated July 20, 2018.
-At the moment the firmware is available as the 
-"Testing" version at the "Support" widget. 
 </code> </code>
  
Line 37: Line 35:
 Global variable registers can be written in either Hardware or Software PLC. Global variable registers can be written in either Hardware or Software PLC.
  
-<code>Q: Why the Frequency Ratio need+<code>Q: Why is the Frequency Ratio needed
-A: Internal frequency unit has no sense for a normal user. It is convenient  +A: Internal frequency units do not make sense for a normal user. It is convenient  
-to set up the ratio and has the Frequency value in a unit usable for a user.  +to set up the ratio and has the Frequency value in a unit that would be usable for a user.  
-Depends on Frequency generator application the unit might be very different.+Depending on the Frequency generator applicationthe unit might be very different.
  
-It can be [1Hz] if you need a simple frequency generator, +It may be [1Hz] if you need a simple frequency generator, 
 or [ml/hour] for Coolant control or [ml/hour] for Coolant control
 or [rpm] for Spindle speed through pulse-dir servo controller. or [rpm] for Spindle speed through pulse-dir servo controller.
Line 51: Line 49:
  
 The first application we used the Pulse Generator was a Coolant control base on a stepper driver. The first application we used the Pulse Generator was a Coolant control base on a stepper driver.
- 
- 
-=== Pulse Generator settings in User Widget === 
-We added Pulse generator settings to a User Widget of "1280M5" profile. We are going to test it and distribute these settings for other profiles and other applications as well later. 
- 
- 
-{{mycnc:generator:mycnc-pulse-coolant-001.png}} 
- 
-The programming of Pulse the Coolant widget is shown below. 
- 
-"user-m5.xml" configuration file contains a code for the User Widget. There are lines to add Coolant widget itself and include a xml file with Coolant widget content 
- 
-<code XML> 
-<gitem  where="user-widget" name="coolant-widget"  
- bgColor="##b-widget"  type="myitems" 
- position="590;300" width="490" height="150" /> 
- 
- <include>user-coolant.xml</include> 
-</code> 
-   
-The lines contain "coolant-widget" definition (a background color, position on the parent widget, a widget size and a widget type (myitems). 
- 
-"user-coolant.xml code is shown below 
- 
-<code XML user-coolant.xml> 
-<mycnc-configuration version="1.0"> 
-<gitem where="coolant-widget" 
- position="0;0" width="490" height="30" labelWidth="490" type="label"  
- labelFgColor="white" labelBgColor="##f-display" labelFontSize="18" labelFontStyle="bold" > 
-  <message>Coolant</message> 
-  <message_ru>Охлаждение</message_ru> 
-  <message_vn>Chất làm mát</message_vn> 
-</gitem> 
- 
-<gitem where="coolant-widget" 
- position="10;40" width="220" height="60" displayWidth="90" labelWidth="130" 
- type="bdisplay" action="item:cnc-gvariable-8133" name="display-cnc-gvariable-8133" 
- bgColor="##b-display" fgColor="##f-display" fontSize="18" fontStyle="bold" format="%5.1f"  
- K="1" labelFontSize="16" labelFontStyle="bold" labelFgColor="white" > 
-  <message>Rate, ml/hour</message> 
-  <message_ru>Расход, мл/час</message_ru> 
-</gitem> 
- 
-<gitem where="coolant-widget" 
- position="280;40" width="180" height="60" displayWidth="90" labelWidth="90" 
- type="bdisplay" action="item:cnc-gvariable-8132" name="display-cnc-gvariable-8132" 
- bgColor="##b-display" fgColor="##f-display" fontSize="14" fontStyle="bold"  
- format="%d" K="1" labelFontSize="16" labelFontStyle="bold" labelFgColor="white" > 
-  <message>Ratio</message> 
-  <message_ru>Коэффициент</message_ru> 
-</gitem> 
- 
-</screen> 
-</code> 
- 
-The code contains 3 parts  
-  * the widget label set up 
-  * the frequency setup 
-  * the Ratio set up 
- 
-It's supposed operator no need to change frequency acceleration and this setting is hidden from an  operator. 
-The acceleration can be set up in the Software or Hardware PLC for example. 
- 
  
 === Pulse Generator settings in the Software PLC === === Pulse Generator settings in the Software PLC ===
-The rate, ratio and acceleration can be set up in the Software PLC as well. +The rate, ratio and acceleration can be set up in the Software PLCas well as in the User Settings widget (the Step-Dir Coolant Control section)
  
-"HANDLER_INIT.plc" procedure is started just after the configuration is sent to the myCNC controller. A few lines to set the Frequency generator can be added there.+"HANDLER_INIT.plc" procedure is started just after the configuration is sent to the myCNC controller. A few lines to set up the Frequency generator can be added there.
  
 <code C HANDLER_INIT.plc> <code C HANDLER_INIT.plc>
Line 134: Line 69:
  
  
-==== (Coolant) Pulse Generator control through Hardware PLC ====+==== MQL (Coolant) Pulse Generator control through Hardware PLC ====
  
-Function coolant_motor_start() is addaed to "mill-func.h" include file+Function ''coolant_motor_start()'' is added to the ''mill-func.h'' file
  
 <code C mill-func.h> <code C mill-func.h>
Line 155: Line 90:
 </code> </code>
  
-M08.plc procedure which starts the coolant motor would be +''M08.plc'' procedure which starts the coolant motor would be the following (//note the inclusion of mill-func.h at the beginning of the code//):
  
 <code C M08.plc> <code C M08.plc>
Line 171: Line 106:
  
  
-A procedure M09.plc to stop a coolant motor is simpler. Just need to write "0" to the raw frequency register.+A procedure ''M09.plc'' to stop a coolant motor is simpler - we simply need to write "0" to the raw frequency register.
  
 <code C M09.plc> <code C M09.plc>
mycnc/independent_pulse_generator.txt · Last modified: 2022/02/11 15:45 by ivan

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki