mycnc:mycnc_configuration_dialogs
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
mycnc:mycnc_configuration_dialogs [2019/07/12 15:18] – ivan | mycnc:mycnc_configuration_dialogs [2019/07/15 09:34] – ivan | ||
---|---|---|---|
Line 127: | Line 127: | ||
=== MPG through binary inputs === | === MPG through binary inputs === | ||
{{: | {{: | ||
- | These settings allow the user to set up MPG through binary inputs | + | These settings allow the user to set up the manual pulse generator |
+ | * Enabled/ | ||
+ | * Input ports number (2 ports needed for an MPG). | ||
+ | * Slot can be changed between MPG (to move the spindle around), THC/Z axis offset for manual control of the z-axis during torch height control, or Spindle Sync to synchronize the vertical z-axis movement and the rotation of the spindle. | ||
+ | * Encoder resolution: number of encoder markings per rotation * number of impulses per marking | ||
+ | |||
+ | As the ET10 controller has dedicated input ports for manual pulse generators, it is not needed to specify 2 different ports but rather one dedicated encoder port number for an ET10 setup. | ||
=== Jog through ADC inputs === | === Jog through ADC inputs === |
mycnc/mycnc_configuration_dialogs.txt · Last modified: 2022/10/28 15:51 by ivan