Line 135: | Line 135: | ||
NOTE: The ET7 controller has the two encoder slots reserved for the ET7 keyboard panel. These are permanently assigned to inputs #16, #17, #18, and #19, and changes in the Config window will not override this preset. If encoder slots are to be used on an ET7 board, the latter two are recommended. This setting is not present on the ET6/ | NOTE: The ET7 controller has the two encoder slots reserved for the ET7 keyboard panel. These are permanently assigned to inputs #16, #17, #18, and #19, and changes in the Config window will not override this preset. If encoder slots are to be used on an ET7 board, the latter two are recommended. This setting is not present on the ET6/ | ||
+ | |||
+ | NOTE #2: The ET10 controller can utilize inputs 0-31 for its binary inputs for an encoder setup. IN32-39 are reserved and are not suited for binary input configurations with an MPG wheel etc. | ||
The full MPG though binary inputs manual is available [[mycnc: | The full MPG though binary inputs manual is available [[mycnc: | ||
Line 927: | Line 929: | ||
{{: | {{: | ||
- | The Hotkeys settings window describes the possible hotkeys which are present in the software. | + | The Hotkeys settings window describes the possible hotkeys which are present in the software. These keys allow the user to control the machine directly from the keyboard, by using some commands which the user can assign to different actions. |
By default, the Shift and Control key are used to set different values of the Jog Overspeed %, allowing the user to quickly control jog speed with a single press. These can be set to be at different percentages (10 and 100 by default). | By default, the Shift and Control key are used to set different values of the Jog Overspeed %, allowing the user to quickly control jog speed with a single press. These can be set to be at different percentages (10 and 100 by default). | ||
Line 942: | Line 944: | ||
{{: | {{: | ||
- | Hardkeys allow the user to connect a button or a key to the myCNC controller which will then cause a certain event when pressed/ | + | Hardkeys allow the user to connect a button or a key directly |
* Input Number, which specifies the input to which the hardkey is connected (can be checked in the Diagnostics window) | * Input Number, which specifies the input to which the hardkey is connected (can be checked in the Diagnostics window) | ||
* Pressed/ | * Pressed/ | ||
Line 972: | Line 974: | ||
The following settings are available: | The following settings are available: | ||
- | * Encoder resolution for each particular encoder number | + | * Encoder resolution for each particular encoder number. |
- | * The current encoder value is displayed on this screen | + | * The current encoder value is displayed on this screen. This is the fastest way to check if the encoder is connected/ |
* Z-position is displayed | * Z-position is displayed | ||
- | * Mul coefficients (multiplication) | + | * Mul coefficients (multiplication |
- | * /(2^Div). These Mul and Div coefficients are used due to the fact that the controller cannot handle floating number data in calculations, | + | * /(2^Div). These Mul and Div coefficients are used due to the fact that the controller cannot handle floating number data in calculations, |
* Encoder position | * Encoder position | ||
* Position | * Position |