mycnc:mycnc_et10
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
mycnc:mycnc_et10 [2019/06/14 12:52] – ivan | mycnc:mycnc_et10 [2019/09/23 09:24] – ivan | ||
---|---|---|---|
Line 78: | Line 78: | ||
< | < | ||
- | {{: | + | {{: |
=== 3-wire PNP sensor connection example (internal power supply)=== | === 3-wire PNP sensor connection example (internal power supply)=== | ||
Line 168: | Line 168: | ||
{{hardware: | {{hardware: | ||
+ | |||
+ | |||
+ | ==== ET10 Firmware Reflash ==== | ||
+ | |||
+ | |||
+ | To reflash the board | ||
+ | |||
+ | {{: | ||
+ | |||
+ | 1. Unplug the 24V DC power supply and detach the ET10 controller from the Breakout board | ||
+ | |||
+ | 2. Plug 24V DC supply | ||
+ | |||
+ | 3. Short power cable between ET1 and Breakout leave connected. | ||
+ | |||
+ | 4. Plug in the mini-USB cable to ET10 & Host Computer with myCNC installed | ||
+ | |||
+ | 5. Close jumpers J4(reset) & J5 (programming) on the myCNC controller board | ||
+ | |||
+ | 6. Open (remove) the J4(reset) jumper. | ||
+ | |||
+ | 7. Open myCNC software on the Host computer, then go to Settings > Support Tab | ||
+ | |||
+ | 8. " | ||
+ | |||
+ | 9. Select " | ||
+ | |||
+ | 10. "UART port" select port with FT232 attached | ||
+ | |||
+ | 11. Baud Rate set to " | ||
+ | |||
+ | 12. Press " | ||
+ | |||
+ | 13. Sector 0 will be written at the end of process, so message in debug window " | ||
+ | |||
+ | 14. Remove all jumpers (J4, J5), assemble TE10 and Breakout and restart the board. | ||
+ | |||
+ | If the reflashing process has failed, please repeat the process from Step 5. | ||
mycnc/mycnc_et10.txt · Last modified: 2023/10/25 12:59 by ivan