User Tools

Site Tools


mycnc:mycnc_et6

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
mycnc:mycnc_et6 [2020/04/27 11:33] ivanmycnc:mycnc_et6 [2022/05/06 16:32] ivan
Line 10: Line 10:
 | RS485/RS422 | 1x RS485 with Modbus ASCII/RTU implementation | | RS485/RS422 | 1x RS485 with Modbus ASCII/RTU implementation |
 | Computer connections | Ethernet (PC/ARM, Linux, MS Windows) | | Computer connections | Ethernet (PC/ARM, Linux, MS Windows) |
 +
 +//Note: The ET8 board is the new updated version of the ET6 controller, which requires unique firmware due to the use of a different chip.// 
  
 ==== ET6 Top View ==== ==== ET6 Top View ====
Line 78: Line 80:
  
 Connector pinouts for ET6 galvanic isolated inputs shown on a picture below Connector pinouts for ET6 galvanic isolated inputs shown on a picture below
-{{:mycnc:007-et6-inputs-connection-001.jpg}}+ 
 +{{:mycnc:et6-inputs-2021-01.jpg}}
  
  
Line 108: Line 111:
 === 3-wire NPN sensor connection example (external power supply)=== === 3-wire NPN sensor connection example (external power supply)===
  
-{{:mycnc:012-et6-npn-external-power-001-v2.jpg}}+{{:mycnc:et6-npn-external-power-2021-01.jpg}}
  
 === 3-wire PNP sensor connection example (external power supply)=== === 3-wire PNP sensor connection example (external power supply)===
-{{:mycnc:013-et6-pnp-external-power-001-v2.jpg}}+ 
 +{{:mycnc:et6-pnp-external-power-2021-01.jpg}}
  
 === 3-wire NPN sensor connection example (internal power supply)=== === 3-wire NPN sensor connection example (internal power supply)===
-{{:mycnc:014-et6-npn-internal-power-001-v2.jpg}}+ 
 +{{:mycnc:et6-npn-internal-power-2021-01.jpg}}
  
 === 3-wire PNP sensor connection example (internal power supply)=== === 3-wire PNP sensor connection example (internal power supply)===
-{{:mycnc:015-et6-pnp-internal-power-001-v2.jpg}}+ 
 +{{:mycnc:et6-pnp-internal-power-2021-01.jpg}}
  
 <code>Depending on the particular sensor, power can be supplied through  <code>Depending on the particular sensor, power can be supplied through 
Line 128: Line 134:
  
 ===Switch connection example (external power supply)=== ===Switch connection example (external power supply)===
-{{:mycnc:017-et6-switch-external-001-v2.jpg}} 
  
-{{:mycnc:018-et6-switch-external-002-v2.jpg}}+{{:mycnc:et6-switch-external-001-2021-01.jpg}} 
 + 
 +{{:mycnc:et6-switch-external-002-2021-01.jpg}}
  
 ==== ET6 control board firmware reflash ==== ==== ET6 control board firmware reflash ====
 +
 +//**WARNING:** Unlike updating the myCNC software, the firmware CANNOT be downgraded after a reflash. The myCNC team recommends reflashing the control board firmware as a last resort only, and recommends seeking an explicit confirmation from the support team that the firmware reflash is warranted in order to avoid issues.// 
  
 {{:mycnc:019-et6-reflash-001.jpg}} {{:mycnc:019-et6-reflash-001.jpg}}
mycnc/mycnc_et6.txt · Last modified: 2023/03/16 09:23 by ivan

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki