mycnc:mycnc_et7 [2019/06/27 13:17] ivanmycnc:mycnc_et7 [2019/06/27 13:43] ivan
Line 283: Line 283:
 To reflash the board: To reflash the board:
  
-  1. Plug in the 24V DC power supply +1. Plug in the 24V DC power supply 
-  2. Plug in the micro-USB cable into the ET7 controller & a Host Computer with myCNC installed + 
-  3. Close jumpers J5(reset) & J6(programming) on the controller board +2. Plug in the micro-USB cable into the ET7 controller & a Host Computer with myCNC installed 
-  4. Open (remove) the J5 jumper.+ 
 +3. Close jumpers J5(reset) & J6(programming) on the controller board 
 + 
 +4. Open (remove) the J5 jumper.
  
 {{:mycnc:et7-reflash-001.png}} {{:mycnc:et7-reflash-001.png}}
  
-  5. Open myCNC software on Host computer (Settings > Support Tab) +5. Open myCNC software on Host computer (Settings > Support Tab)
-  6. "Select board" set to "myCNC-ET7" +
-  7. Select "Firmware version" from "Release", "Night build" or "Testing" +
-  8. "UART port" select port with FT232 attached +
-  9. Baud Rate set to "115200" for ET7; other baudrate can be selected in case of problems on 115200 speed +
-  10. Press "Update Firmware" button, Firmware download and reflashing process will be started. +
-  11. If "Sector 0; +" message is shown in the debug window, the reflashing process has finished successfully. +
-  12. Remove all jumpers (J4, J5) and restart the board.+
  
-If the reflashing process failed, please repeat the procedure from Step 3. +6"Select board" set to "myCNC-ET7"
-   +
-{{:mycnc:et7-reflash-002-support.png}}+
  
 +7. Select "Firmware version" from "Release", "Night build" or "Testing" ("Release" is recommended)
  
 +8. "UART port" - select the port with FT232 attached. If no such port visible, check the micro-USB connection, then close and open the Support tab once again in order to refresh it. 
  
 +9. Baud Rate set to "115200" for ET7; other baudrate can be selected in case of problems on the 115200 speed
 +
 +10. Press "Update Firmware" button, Firmware download and reflashing process will be started
 +
 +11. If "Sector 0; +" message is shown in the debug window, the reflashing process has been finished successfully.
 +
 +12. Remove all jumpers (J4, J5) and restart the board.
 +  
 +{{:mycnc:et7-reflash-002-support.png}}
 +
 +If the reflashing process failed, please repeat the procedure from Step 3.

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki