plc:oil_change_counter [2017/12/09 11:01] esplc:oil_change_counter [2017/12/11 00:26] (current) es
Line 9: Line 9:
 We take **1280M5** profile as based profile to add **Oil Change Counter **. We take **1280M5** profile as based profile to add **Oil Change Counter **.
  
 +
 +{{mycnc:mycnc-oil-change--1.png}}
 +
 +
 +<code c>
 +main()
 +{
 +//touch global variables 6890,6891,6892 to save its values in cnc-variables.xml
 +gvarset(6890,gvarget(6890));
 +gvarset(6891,gvarget(6891));
 +gvarset(6892,gvarget(6892));
 +
 +//get initial machine coordinates  for x,y,z
 +pos_x=gvarget(5021);
 +pos_y=gvarget(5022);
 +pos_z=gvarget(5023);
 +
 +//initialize ticks counter
 +ticks=0;
 +
 +
 +//endless loop to handle Oil-Change Counter
 +do{
 +
 +//read limit Limit values for all axes x,y,x and arrange it to Meters
 +limit_x=gvarget(6890)*1000;
 +limit_y=gvarget(6891)*1000;
 +limit_z=gvarget(6892)*1000;
 +
 +
 +//X axis handler
 +//Check if X position changed
 +dx=pos_x-gvarget(5021);
 +if (dx!=0)
 +{
 + pos_x=gvarget(5021);//update changes
 + if (dx<0){dx=0-dx;};//get absoluet value of x moves
 +//check move length does not exceed 10mm (to exclude possible error)
 +//and add move length to variable #6090
 + if (dx<10){gvarset(6090,gvarget(6090)+dx); };
 +};
 +
 +//Y axis handler
 +dy=pos_y-gvarget(5022);
 +if (dy!=0)
 +{
 + pos_y=gvarget(5022);
 + if (dy<0){dy=0-dy;};
 + if (dy<10){gvarset(6091,gvarget(6091)+dy); };
 +};
 +
 +//Z axis handler
 +dz=pos_z-gvarget(5023);
 +if (dy!=0)
 +{
 + pos_z=gvarget(5023);
 + if (dz<0){dz=0-dz;};
 + if (dz<10){gvarset(6092,gvarget(6092)+dz); };
 +};
 +
 +
 +
 +//Check is any axis mileage exceed limit
 +alarm=0;
 +if (gvarget(6090)>limit_x) { alarm=1; };
 +if (gvarget(6091)>limit_y) { alarm=1; };
 +if (gvarget(6092)>limit_z) { alarm=1; };
 +
 +
 +
 +//In case Oil-Change event handle varaible #6085 blink 1 time per second
 +if (alarm!=0)
 +{
 +  ticks++;
 +  if (ticks<8) {gvarset(6085,0);}
 +  else {gvarset(6085,1);};
 +
 +  if (ticks>10) {ticks=0;};
 +}else
 +{
 +  gvarset(6085,0);portclr(0);
 +};
 +
 +
 +}while(1);
 +
 +
 +exit(99);
 +};
 +
 +</code>