Line 32: Line 32:
 === PLC Language === === PLC Language ===
  
-  * PLC operates with 32 bits integer values only. Floating point operations don't work in PLC.+  * PLC operates with 32 bits integer values only. Floating point operations don't work in PLC (typically need to use coefficient conversions to allow for more granular control).
   * There is no need to declare variables. There is very limited space of 32 elements for variables.    * There is no need to declare variables. There is very limited space of 32 elements for variables. 
   * There a number of pre-defined variables in the PLC   * There a number of pre-defined variables in the PLC
-    * eparam - External Parameter variable. If M-code running from G-code program, 16-bit integer parameters P and L are sent to the PLC procedure in the **eparam** variable. \\ P-parameter in a low word of the eparam value and \\ L-parameter in high word of eparam value. To decode P and L parameters from **eparam** simple 2-lines code can be used <code>P=eparam&0xFFFF;//P-parameter +    * eparam - External Parameter variable. A short manual is available here: [[plc:plc:eparam|Eparam]] 
-L=eparam>>16; //L-parameter</code>+
     * **proc** - variable is used to identify a process running in the PLC. \\ The value is sent to the CNC control software and can be used to display Current PLC state (like Idle, Ignition (for plasma cutting), preheat (gas cutting), Tool change, Probing etc)     * **proc** - variable is used to identify a process running in the PLC. \\ The value is sent to the CNC control software and can be used to display Current PLC state (like Idle, Ignition (for plasma cutting), preheat (gas cutting), Tool change, Probing etc)
     * **timer** - value can be used as time counter inside PLC procedure     * **timer** - value can be used as time counter inside PLC procedure
Line 85: Line 84:
 ^ Address ^ Description ^ ^ Address ^ Description ^
 | 20000...20100 | Print variable value in myCNC control message widget for debugging purpose. Values written to this registers will be printed in myCNC control software in Message widget {{mycnc:mycnc-print-variable-001.png?600}} | | 20000...20100 | Print variable value in myCNC control message widget for debugging purpose. Values written to this registers will be printed in myCNC control software in Message widget {{mycnc:mycnc-print-variable-001.png?600}} |
 +
 +It is possible to access the state of the output via gvarget commands from within the PLC process:
 +
 +<code>a=gvarget(0x400); //OUT0
 +b=gvarget(0x407); //OUT7</code>
 +
 +Starting from 0x400 to represent OUT0, this is a hexadecimal system that is simple to convert to dotted decimals (through the likes of a simple reference site [[https://www.hexadecimaldictionary.com/hexadecimal/0x400/|here]]). Thus, for example, //gvarget(0x40d);// will return the state of Output #13. 
 +
  