 ^ Address ^ Description ^ ^ Address ^ Description ^
 | 20000...20100 | Print variable value in myCNC control message widget for debugging purpose. Values written to this registers will be printed in myCNC control software in Message widget {{mycnc:mycnc-print-variable-001.png?600}} | | 20000...20100 | Print variable value in myCNC control message widget for debugging purpose. Values written to this registers will be printed in myCNC control software in Message widget {{mycnc:mycnc-print-variable-001.png?600}} |
 +
 +It is possible to access the state of the output via gvarget commands from within the PLC process:
 +
 +<code>a=gvarget(0x400); //OUT0
 +b=gvarget(0x407); //OUT7</code>
 +
 +Starting from 0x400 to represent OUT0, this is a hexadecimal system that is simple to convert to dotted decimals (through the likes of a simple reference site [[https://www.hexadecimaldictionary.com/hexadecimal/0x400/|here]]). Thus, for example, //gvarget(0x40d);// will return the state of Output #13. 
 +
  
 === The hardware access registers === === The hardware access registers ===
plc/plc.txt · Last modified: 2022/11/07 16:03 by ivan