Line 14: | Line 14: | ||
^ Variable Name ^ Value ^ Comment ^ | ^ Variable Name ^ Value ^ Comment ^ | ||
+ | ^ THC #1 Registers ^^^ | ||
| GVAR_THC0_CONTROL | 7570 | THC #0 Control register.\\ Writing 0 to this register will turn THC off.\\ Writing 1 - Immediate (No delay) start THC\\ with pre-defined | | GVAR_THC0_CONTROL | 7570 | THC #0 Control register.\\ Writing 0 to this register will turn THC off.\\ Writing 1 - Immediate (No delay) start THC\\ with pre-defined | ||
| GVAR_THC0_INPUT | 7571 | Writing to this register will change ADC channel\\ used for THC control.\\ ADC numeration starts from 0x10\\ 0x10 - ADC #0\\ 0x11 - ADC #1\\ 0x12 - ADC #2\\ 0x13 - ADC #3\\ 0x14 - ADC #4\\ 0x15 - ADC #5\\ 0x16 - ADC #6\\ 0x17 - ADC #7\\ | | | GVAR_THC0_INPUT | 7571 | Writing to this register will change ADC channel\\ used for THC control.\\ ADC numeration starts from 0x10\\ 0x10 - ADC #0\\ 0x11 - ADC #1\\ 0x12 - ADC #2\\ 0x13 - ADC #3\\ 0x14 - ADC #4\\ 0x15 - ADC #5\\ 0x16 - ADC #6\\ 0x17 - ADC #7\\ | |
plc/plc_thc_api.txt · Last modified: 2017/11/10 11:40 by skirillov