-^ THC #Registers ^^^+^ THC #Registers ^^^
 | GVAR_THC0_CONTROL | 7570 | THC #0 Control register.\\ Writing 0 to this register will turn THC off.\\ Writing 1 - Immediate (No delay) start THC\\ with pre-defined  Reference Value\\ Writing 2 - Start THC with Delay\\ (THC on delay parameter in THC settings) and pre-defined Reference Value\\ Writing 3 - Update Reference Value (Measure ADC channel)\\ and Immediate Start THC with new Reference\\ Writing 4 - After Delay update Reference Value\\ (Measure ADC channel) and Start THC with new Reference | | GVAR_THC0_CONTROL | 7570 | THC #0 Control register.\\ Writing 0 to this register will turn THC off.\\ Writing 1 - Immediate (No delay) start THC\\ with pre-defined  Reference Value\\ Writing 2 - Start THC with Delay\\ (THC on delay parameter in THC settings) and pre-defined Reference Value\\ Writing 3 - Update Reference Value (Measure ADC channel)\\ and Immediate Start THC with new Reference\\ Writing 4 - After Delay update Reference Value\\ (Measure ADC channel) and Start THC with new Reference |
 | GVAR_THC0_INPUT | 7571 | Writing to this register will change ADC channel\\ used for THC control.\\ ADC numeration starts from 0x10\\ 0x10 - ADC #0\\ 0x11 - ADC #1\\ 0x12 - ADC #2\\ 0x13 - ADC #3\\ 0x14 - ADC #4\\ 0x15 - ADC #5\\ 0x16 - ADC #6\\ 0x17 - ADC #7\\ | | GVAR_THC0_INPUT | 7571 | Writing to this register will change ADC channel\\ used for THC control.\\ ADC numeration starts from 0x10\\ 0x10 - ADC #0\\ 0x11 - ADC #1\\ 0x12 - ADC #2\\ 0x13 - ADC #3\\ 0x14 - ADC #4\\ 0x15 - ADC #5\\ 0x16 - ADC #6\\ 0x17 - ADC #7\\ |
Line 38: Line 38:
 | GVAR_THC3_OFFSETZ | 7588 | See THC #0 above | | GVAR_THC3_OFFSETZ | 7588 | See THC #0 above |
 | GVAR_THC3_ENABLED | 7589 | See THC #0 above | | GVAR_THC3_ENABLED | 7589 | See THC #0 above |
 +
 +
 +Examples.
 +Switch On THC#0 and THC#1 in **M03** Oxyfuel Gas Cutting ON procedure (2x gas cutting heads configuration). Pre-defined Reference Value is used, THC will be started after delay, defined in Cfg->Technology->THC configuration dialog, **THC delay, s** item.
 +<code>
 +if (thc_enabled!=0)
 + {
 +   gvarset(7570,1); //THC #0 ON
 +   gvarset(7575,1); //THC #1 ON
 + };
 +</code>
 +
 +
 +Switch Off THC#0 and THC#1 in **M05** Oxyfuel Gas Cutting OFF procedure (2x gas cutting heads configuration)
 +<code>
 +   gvarset(7570,0); //THC #0 ON
 +   gvarset(7575,0); //THC #1 ON
 +</code>
 +
 +
  