thc:thc [2019/11/05 15:00] ivanthc:thc [2019/11/05 15:01] ivan
Line 152: Line 152:
 {{:thc:thc-setup-012-diagram.png}} {{:thc:thc-setup-012-diagram.png}}
  
-  * IHC Correction Height. The correction height is typically set once per machine, and signifies the correction between the IHC sensor and the actual height of the plasma torch. Read more about the IHC Correction height in the [[mycnc:ihc|IHC manual]]. +  * **IHC Correction Height**. The correction height is typically set once per machine, and signifies the correction between the IHC sensor and the actual height of the plasma torch. Read more about the IHC Correction height in the [[mycnc:ihc|IHC manual]]. 
-  * IHC Ignition Height. After contact, the torch rises to the Ignition Height and waits for the arc signal.  +  * **IHC Ignition Height**. After contact, the torch rises to the Ignition Height and waits for the arc signal.  
-  * IHC Pierce Height. After receiving the arc signal, the torch rises to the pierce height and begins the pierce procedure. +  * **IHC Pierce Height**. After receiving the arc signal, the torch rises to the pierce height and begins the pierce procedure. 
-  * IHC Pierce Time. The pierce time specifies the amount of time, in seconds, allocated to the pierce procedure.  +  * **IHC Pierce Time**. The pierce time specifies the amount of time, in seconds, allocated to the pierce procedure.  
-  * IHC Cutting Height. After the pierce time has elapsed, the machine moves the torch to the cutting height at which the cutting will begin. +  * **IHC Cutting Height**. After the pierce time has elapsed, the machine moves the torch to the cutting height at which the cutting will begin. 
-  * THC Start Delay signifies the time for which Torch Height Control is not turned on after the cutting has started (to prevent metal splashes/voltage variations that are often present at the beginning of the cut to impact the cutting procedure). This delay can be set to ON or OFF in the User Settings.  +  * **THC Start Delay** signifies the time for which Torch Height Control is not turned on after the cutting has started (to prevent metal splashes/voltage variations that are often present at the beginning of the cut to impact the cutting procedure). This delay can be set to ON or OFF in the User Settings.  
-  * THC Pre-off time. In order to prevent sudden movements due to rapid voltage changes as a cut (especially when cutting a hole) is done, THC can be turned off some time before the end of the cut and the machine will be kept at a set height until the THC system will move to the next cut. +  * **THC Pre-off time**. In order to prevent sudden movements due to rapid voltage changes as a cut (especially when cutting a hole) is done, THC can be turned off some time before the end of the cut and the machine will be kept at a set height until the THC system will move to the next cut. 
-  * Lift After Cut Height to move the torch up to after the cut has completed. +  * **Lift After Cut Height** to move the torch up to after the cut has completed. 
  