<?xml version="1.0" encoding="UTF-8"?>
<!-- generator="FeedCreator 1.8" -->
<?xml-stylesheet href="https://docs.pv-automation.com/lib/exe/css.php?s=feed" type="text/css"?>
<rdf:RDF
    xmlns="http://purl.org/rss/1.0/"
    xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#"
    xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
    xmlns:dc="http://purl.org/dc/elements/1.1/">
    <channel rdf:about="https://docs.pv-automation.com/feed.php">
        <title>myCNC Online Documentation - other</title>
        <description></description>
        <link>https://docs.pv-automation.com/</link>
        <image rdf:resource="https://docs.pv-automation.com/_media/wiki/logo.png" />
       <dc:date>2026-04-28T09:03:58+00:00</dc:date>
        <items>
            <rdf:Seq>
                <rdf:li rdf:resource="https://docs.pv-automation.com/other/5v-converters?rev=1698759215&amp;do=diff"/>
                <rdf:li rdf:resource="https://docs.pv-automation.com/other/access_files?rev=1679492165&amp;do=diff"/>
                <rdf:li rdf:resource="https://docs.pv-automation.com/other/console_commands?rev=1618326588&amp;do=diff"/>
                <rdf:li rdf:resource="https://docs.pv-automation.com/other/importing-essi-files?rev=1559308978&amp;do=diff"/>
                <rdf:li rdf:resource="https://docs.pv-automation.com/other/language-localization?rev=1730388891&amp;do=diff"/>
                <rdf:li rdf:resource="https://docs.pv-automation.com/other/manual_firmware_reflash?rev=1689168467&amp;do=diff"/>
                <rdf:li rdf:resource="https://docs.pv-automation.com/other/npn-sensor-to-ttl-input?rev=1499210489&amp;do=diff"/>
                <rdf:li rdf:resource="https://docs.pv-automation.com/other/rustdesk?rev=1767801514&amp;do=diff"/>
                <rdf:li rdf:resource="https://docs.pv-automation.com/other/samba-connection?rev=1681477169&amp;do=diff"/>
                <rdf:li rdf:resource="https://docs.pv-automation.com/other/sheetcam?rev=1644859463&amp;do=diff"/>
                <rdf:li rdf:resource="https://docs.pv-automation.com/other/smd_resistor_codes?rev=1633702671&amp;do=diff"/>
            </rdf:Seq>
        </items>
    </channel>
    <image rdf:about="https://docs.pv-automation.com/_media/wiki/logo.png">
        <title>myCNC Online Documentation</title>
        <link>https://docs.pv-automation.com/</link>
        <url>https://docs.pv-automation.com/_media/wiki/logo.png</url>
    </image>
    <item rdf:about="https://docs.pv-automation.com/other/5v-converters?rev=1698759215&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2023-10-31T13:33:35+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>5v-converters</title>
        <link>https://docs.pv-automation.com/other/5v-converters?rev=1698759215&amp;do=diff</link>
        <description>Line driver to 5V converters

In cases where the driver (such as ClearPath) would only activate above a certain threshold due to the difference between the required and the provided signal from the control board due to the design of the driver/motor, the Puruvesi Automation advises to use a line driver to 5V converter.</description>
    </item>
    <item rdf:about="https://docs.pv-automation.com/other/access_files?rev=1679492165&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2023-03-22T13:36:05+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>access_files</title>
        <link>https://docs.pv-automation.com/other/access_files?rev=1679492165&amp;do=diff</link>
        <description>How to access files on a non-working PC

In a scenario where the PC will not boot or cannot be accessed, it may be necessary to still retrieve some files off of its hard drive (for instance, myCNC profile folders that contain all the custom settings for the myCNC software).</description>
    </item>
    <item rdf:about="https://docs.pv-automation.com/other/console_commands?rev=1618326588&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2021-04-13T15:09:48+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>console_commands</title>
        <link>https://docs.pv-automation.com/other/console_commands?rev=1618326588&amp;do=diff</link>
        <description>Console commands

The following console commands can be used for programming, reflashing of configuring the myCNC controller. The controller should be connected to PC through a USB-slave connector.

Serial connection is used with parameters 115200 8N1.</description>
    </item>
    <item rdf:about="https://docs.pv-automation.com/other/importing-essi-files?rev=1559308978&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2019-05-31T13:22:58+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>importing-essi-files</title>
        <link>https://docs.pv-automation.com/other/importing-essi-files?rev=1559308978&amp;do=diff</link>
        <description>Working with AJAN CAM software

Creating the CAD/CAM file

In order to import ESSI/MPG files into myCNC software, we can first use a CAM/CAD program like AJAN CAM to obtain the file itself. Programs like AJAN CAM are often used to create CAD drawings for plasma or laser cutting, which can later be converted and imported into myCNC.</description>
    </item>
    <item rdf:about="https://docs.pv-automation.com/other/language-localization?rev=1730388891&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2024-10-31T15:34:51+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>language-localization</title>
        <link>https://docs.pv-automation.com/other/language-localization?rev=1730388891&amp;do=diff</link>
        <description>Language Localization

A number of language localization packages, some of them full while others partial, are already included in the myCNC software. In order to switch the application language, head into Settings &gt; Config &gt; Screen, and type a two-digit language code into the language field, press Save CFG and reload the application for the change to take effect:</description>
    </item>
    <item rdf:about="https://docs.pv-automation.com/other/manual_firmware_reflash?rev=1689168467&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2023-07-12T13:27:47+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>manual_firmware_reflash</title>
        <link>https://docs.pv-automation.com/other/manual_firmware_reflash?rev=1689168467&amp;do=diff</link>
        <description>Firmware Reflash

As of June 2023, the boards sold by Puruvesi Automation feature the simplified process of updating the controller firmware via the bootloader-firmware-update command that can be assigned to a button or a GUI element within a myCNC profile. Normally, when using the button which features this command, the process consists of simply pressing the</description>
    </item>
    <item rdf:about="https://docs.pv-automation.com/other/npn-sensor-to-ttl-input?rev=1499210489&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2017-07-04T23:21:29+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>npn-sensor-to-ttl-input</title>
        <link>https://docs.pv-automation.com/other/npn-sensor-to-ttl-input?rev=1499210489&amp;do=diff</link>
        <description>How to connect 24V NPN sensor to TTL input of CNC control board with optocouple



How to connect Contact sensor to ET6/ET7/ET10 optoisolated input</description>
    </item>
    <item rdf:about="https://docs.pv-automation.com/other/rustdesk?rev=1767801514&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2026-01-07T15:58:34+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>rustdesk</title>
        <link>https://docs.pv-automation.com/other/rustdesk?rev=1767801514&amp;do=diff</link>
        <description>RustDesk installation

Windows installation

Installing RustDesk on Windows can be done using the following steps (Windows 10 shown in the examples below):

1) Navigate to the &lt;https://rustdesk.com/&gt; website and click on the Download button:



2) Select the latest release version from the GitHub page that pops up. In this example, we will be using version 1.4.4 and selecting the x86-64 (64-bit) EXE, which is the first link in the Windows column.</description>
    </item>
    <item rdf:about="https://docs.pv-automation.com/other/samba-connection?rev=1681477169&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2023-04-14T12:59:29+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>samba-connection</title>
        <link>https://docs.pv-automation.com/other/samba-connection?rev=1681477169&amp;do=diff</link>
        <description>Connection between Windows and Linux machines through a Samba server

Connecting to a Linux machine through Windows 7/10


Samba should work out of the box on new (as of January 2020) images of Ubuntu Mate provided by the myCNC team. Use the steps below to set up a Samba server</description>
    </item>
    <item rdf:about="https://docs.pv-automation.com/other/sheetcam?rev=1644859463&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2022-02-14T17:24:23+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>sheetcam</title>
        <link>https://docs.pv-automation.com/other/sheetcam?rev=1644859463&amp;do=diff</link>
        <description>SheetCam Tips

Path rules

SheetCam allows the user to set a combination of path rules. In the example below, the path rules result in a decrease in speed on given sections of the workpath.

SheetCam screenshot:


Result in myCNC:


As can be noted from the Path Rules, the example above will have a speed reduction to 40% of the original speed at the arcs on each of the part&#039;s corners.</description>
    </item>
    <item rdf:about="https://docs.pv-automation.com/other/smd_resistor_codes?rev=1633702671&amp;do=diff">
        <dc:format>text/html</dc:format>
        <dc:date>2021-10-08T14:17:51+00:00</dc:date>
        <dc:creator>Anonymous (anonymous@undisclosed.example.com)</dc:creator>
        <title>smd_resistor_codes</title>
        <link>https://docs.pv-automation.com/other/smd_resistor_codes?rev=1633702671&amp;do=diff</link>
        <description>EIA96 SMD resistor code system

EIA SMD Resistor Code Scheme
Code  Multiplier Z  0.001 Y or R  0.01 X or S  0.1 A  1 B or H  10 C  100 D  1 000 E  10 000 F  100 000 
EIA SMD Resistor Code Scheme Multipliers
 Code  Sig Figs  Code  Sig Figs  Code  Sig Figs</description>
    </item>
</rdf:RDF>
