faq
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
faq [2019/12/31 13:41] – ivan | faq [2020/04/27 09:43] – ivan | ||
---|---|---|---|
Line 5: | Line 5: | ||
++++ Is a PC required to use the myCNC controller? | | ++++ Is a PC required to use the myCNC controller? | | ||
- | Yes, a PC is required to run the myCNC software, which will be used to control the myCNC board. You can use a full industrial PC (such as the one provided in some controller kits in our Shop), or you can use a small single board computer, such as a Raspberry Pi, an Odroid or a TinkerBoard. The links to download the myCNC software are available at our [[https:// | + | Yes, a PC is required to run the myCNC software, which will be used to control the myCNC board. You can use a full industrial PC (such as the one provided in some controller kits in our Shop), or you can use a small single board computer, such as a Raspberry Pi, an Odroid or a TinkerBoard. The links to download the myCNC software are available at our [[https:// |
++++ | ++++ | ||
- | ++++ Why is there no connection between my computer and the myCNC controller? | | + | ++++ Is a myCNC controller |
- | If there doesn' | + | Yes, a myCNC controller is needed |
+ | |||
+ | The software can be downloaded | ||
+ | |||
+ | ++++ | ||
+ | |||
+ | |||
+ | ====Software Setup==== | ||
+ | |||
+ | |||
+ | ++++ What are the login credentials for a computer running | ||
+ | |||
+ | The login credentials for all Linux computers using the myCNC Ubuntu MATE installation are the following: | ||
+ | |||
+ | Login: **mycnc** | ||
+ | Password: **operator** | ||
+ | |||
+ | ++++ | ||
+ | |||
+ | ++++ How do I navigate | ||
+ | |||
+ | A short introduction to myCNC software is available here: | ||
+ | |||
+ | {{youtube> | ||
+ | |||
+ | If you would like more information about all the particular buttons | ||
+ | |||
+ | ++++ | ||
+ | |||
+ | ++++ How to load G-code or DXF files into the software? | | ||
+ | |||
+ | The files that you are attempting to load must be located in folders that are specified in the **Settings > Config > Preferences | ||
+ | |||
+ | {{::forum-mar2020-002-code-folders.png}} | ||
+ | |||
+ | If a folder is not listed | ||
+ | |||
+ | The following standard folders are used on Linux (Ubuntu MATE) installations: | ||
+ | |||
+ | '' | ||
+ | |||
+ | '' | ||
+ | |||
+ | The '' | ||
+ | |||
+ | The following standard folders are used on Windows installations: | ||
+ | |||
+ | '' | ||
+ | |||
+ | '' | ||
+ | |||
+ | After you have listed the folders that you would like to have access to, you can open files using the **Open G-code** and **Open DXF** buttons from the main software screen: | ||
+ | |||
+ | {{:: | ||
++++ | ++++ | ||
Line 18: | Line 71: | ||
The procedure to update the myCNC application is described in detail in the following manual: [[mycnc: | The procedure to update the myCNC application is described in detail in the following manual: [[mycnc: | ||
+ | |||
+ | Here is a short video going through the steps to update the application: | ||
+ | |||
+ | {{youtube> | ||
++++ | ++++ | ||
Line 30: | Line 87: | ||
If updating manually, many users also prefer to keep their PLC folder intact to make sure any changes unique to their setups do not get overwritten by the default configuration. | If updating manually, many users also prefer to keep their PLC folder intact to make sure any changes unique to their setups do not get overwritten by the default configuration. | ||
+ | |||
+ | ++++ | ||
+ | |||
+ | ++++ How to switch the profile / technology? | | ||
+ | |||
+ | In order to switch the current technology / profile within the software (for example, to switch from the Mill profile to a Plasma profile, or from a Plasma profile to Tangential Cutting): | ||
+ | |||
+ | * Go into Settings > Info | ||
+ | * In the right panel, select the profile you'd like to switch to (for example, X1366P) | ||
+ | * Click the Save Profile button | ||
+ | * Reload the application | ||
+ | |||
+ | {{:: | ||
+ | |||
+ | The myCNC software should now switch to the chosen technology profile. | ||
++++ | ++++ | ||
Line 49: | Line 121: | ||
- | ++++ Why is the machine not moving despite the on-screen coordinates changing? | | + | ++++ How to set up homing? | |
- | If after the motors have been connected, the machine isn't moving despite the on-screen coordinates changing while pressing the jog keys, the pulse width might be set up incorrectly, | + | The following video is available |
- | Typically, if using a stepper motor, a higher setting number than the default should be chosen in order to allow the machine to register the pulses sent to it. | + | {{youtube> |
- | NOTE: The first value in the Pulse Width field in the myCNC settings refers to the first four movement directions for the controller (for example, X+, X-, Y+ and Y-), while the second value refers to the last two movement directions (for example, Z+ and Z-). Typically, these fields should be set to the same value, however they can be different if different drivers are used on the last two axes (motors 5 and 6) as compared to motors 1 through 4. | + | A full manual is available here: [[quickstart: |
++++ | ++++ | ||
+ | ++++ How to remove the homing dialog that keeps popping up when starting the program? | | ||
- | ++++ What to do if it seems like there is something wrong with the hardware? | | + | {{youtube> |
- | + | ||
- | First of all, go through the relevant hardware troubleshooting checklist available here: [[troubleshooting: | + | |
- | + | ||
- | If using an ET10 board, check that it was assembled correctly, using the images in this forum thread as reference: [[http:// | + | |
- | + | ||
- | If nothing comes up, write to us using our [[https:// | + | |
- | + | ||
- | ++++ | + | |
- | + | ||
- | ++++ How to remove the homing dialog that keeps popping up when starting the program? | | + | |
The homing dialog is done through the HOMING_HANDLER Software PLC. If you would like to disable it, add a line saying exit(99); near the start of the code like so: | The homing dialog is done through the HOMING_HANDLER Software PLC. If you would like to disable it, add a line saying exit(99); near the start of the code like so: | ||
Line 80: | Line 143: | ||
< | < | ||
- | ++++ | + | For more information |
- | + | ||
- | + | ||
- | ++++ Why do ports turn on/off automatically when opening and closing the program? | | + | |
- | + | ||
- | Check the _HANDLER_INIT and _HANDLER_EXIT Software PLCs for the starting and closing commands respectively (specifically, the '' | + | |
- | + | ||
- | {{::faq-qs-004-sofware-plc.png}} | + | |
- | + | ||
- | The '' | + | |
++++ | ++++ | ||
Line 96: | Line 149: | ||
++++ How to change Screen Size and Position | | ++++ How to change Screen Size and Position | | ||
- | Open **Settings** Tab | + | * Open **Settings** Tab |
- | Open the **Config** Tab | + | |
- | + | * Select **Preferences**, | |
- | {{mycnc: | + | |
- | Select **Preferences**, | + | {{::faq-qs-010-screen-size.png}} |
- | {{mycnc:mycnc-language-select-8.png}} | + | |
There are few settings to control GUI screen size, position and window attributes | There are few settings to control GUI screen size, position and window attributes | ||
Line 116: | Line 167: | ||
DOES depend on OS/Window Manager. You might need to play with these settings to find a view | DOES depend on OS/Window Manager. You might need to play with these settings to find a view | ||
suitable for your needs.</ | suitable for your needs.</ | ||
- | |||
- | ++++ | ||
- | |||
- | ++++ Why do ClearPath drivers not work out of the box? | | ||
- | |||
- | ClearPath drivers will not out of the box unless using the line driver to 5V converters. Here is the official explanation from the ClearPath website as to why the ClearPath drivers are not directly compatible: | ||
- | |||
- | {{:: | ||
- | |||
- | Effectively, | ||
- | |||
- | More information about the converter boards is available here: [[other: | ||
++++ | ++++ | ||
Line 152: | Line 191: | ||
++++ | ++++ | ||
- | ++++Why does the Parts Library not show certain parts? | | + | ++++ How to change |
- | When entering the Parts Library, you may be greeted with an empty page, or a page that's missing some parts that are supposed | + | A quick video on switching mm to inches is available: |
- | {{: | + | {{youtube> |
- | + | ||
- | To remedy this, head into Settings > Config > Preferences > Shape Library Settings and make sure that the necessary libraries are selected by clicking the checkmark field. This setting is present to allow the operator to disregard all the part libraries which are not necessary for their particular machine: | + | |
- | + | ||
- | {{: | + | |
- | + | ||
- | Save and reload the application, | + | |
- | + | ||
- | {{: | + | |
++++ | ++++ | ||
Line 187: | Line 218: | ||
* **Edit XML config item** experimental dialog will be shown. | * **Edit XML config item** experimental dialog will be shown. | ||
* Find a line with attribute " | * Find a line with attribute " | ||
+ | |||
+ | ++++ | ||
+ | |||
+ | ++++ How does the Run from Here procedure work? | | ||
+ | |||
+ | {{youtube> | ||
+ | |||
+ | In an event of an emergency stop or failure of a mill machine running a program file, it is often useful to be able to open the file back up afterwards and be able to continue from the middle of the program without having to go through all the steps again. This is often complicated by the fact that a large program file consists of many lines of code, making it difficult to easily navigate to the place where the cutting process stopped initially. In order to facilitate finding this spot, the Run from Here process is put in place in myCNC software. | ||
+ | |||
+ | The Run from Here method is described in the following section of the myCNC Screen manual: [[http:// | ||
+ | |||
+ | ++++ | ||
+ | |||
+ | ==== Troubleshooting ==== | ||
+ | |||
+ | ++++ Why is there no connection between my computer and the myCNC controller? | | ||
+ | |||
+ | If there doesn' | ||
+ | |||
+ | ++++ | ||
+ | |||
+ | ++++ Why do ports turn on/off automatically when opening and closing the program? | | ||
+ | |||
+ | Check the _HANDLER_INIT and _HANDLER_EXIT Software PLCs for the starting and closing commands respectively (specifically, | ||
+ | |||
+ | {{:: | ||
+ | |||
+ | The '' | ||
+ | |||
+ | ++++ | ||
+ | |||
+ | ++++ Why is the machine not moving despite the on-screen coordinates changing? | | ||
+ | |||
+ | If after the motors have been connected, the machine isn't moving despite the on-screen coordinates changing while pressing the jog keys, the pulse width might be set up incorrectly, | ||
+ | |||
+ | Typically, if using a stepper motor, a higher setting number than the default should be chosen in order to allow the machine to register the pulses sent to it. | ||
+ | |||
+ | NOTE: The first value in the Pulse Width field in the myCNC settings refers to the first four movement directions for the controller (for example, X+, X-, Y+ and Y-), while the second value refers to the last two movement directions (for example, Z+ and Z-). Typically, these fields should be set to the same value, however they can be different if different drivers are used on the last two axes (motors 5 and 6) as compared to motors 1 through 4. | ||
+ | |||
+ | ++++ | ||
+ | |||
+ | |||
+ | ++++ What to do if it seems like there is something wrong with the hardware? | | ||
+ | |||
+ | First of all, go through the relevant hardware troubleshooting checklist available here: [[troubleshooting: | ||
+ | |||
+ | If using an ET10 board, check that it was assembled correctly, using the images in this forum thread as reference: [[http:// | ||
+ | |||
+ | If nothing comes up, write to us using our [[https:// | ||
+ | |||
+ | ++++ | ||
+ | |||
+ | ++++Why does the Parts Library not show certain parts? | | ||
+ | |||
+ | When entering the Parts Library, you may be greeted with an empty page, or a page that's missing some parts that are supposed to be there: | ||
+ | |||
+ | {{: | ||
+ | |||
+ | To remedy this, head into Settings > Config > Preferences > Shape Library Settings and make sure that the necessary libraries are selected by clicking the checkmark field. This setting is present to allow the operator to disregard all the part libraries which are not necessary for their particular machine: | ||
+ | |||
+ | {{: | ||
+ | |||
+ | Save and reload the application, | ||
+ | |||
+ | {{: | ||
+ | |||
+ | ++++ | ||
+ | |||
+ | |||
+ | ++++ Why do ClearPath drivers not work out of the box? | | ||
+ | |||
+ | ClearPath drivers will not out of the box unless using the line driver to 5V converters. Here is the official explanation from the ClearPath website as to why the ClearPath drivers are not directly compatible: | ||
+ | |||
+ | {{:: | ||
+ | |||
+ | Effectively, | ||
+ | |||
+ | More information about the converter boards is available here: [[other: | ||
++++ | ++++ | ||
Line 217: | Line 326: | ||
{{youtube> | {{youtube> | ||
+ | |||
+ | In general, the Back to Path button is generally used on plasma machines, while the On-Start/ | ||
+ | |||
+ | ++++ | ||
=====Tangential Knife===== | =====Tangential Knife===== | ||
++++ Why is the knife not turning when using the Tangential Knife profile (X1366V)? | | ++++ Why is the knife not turning when using the Tangential Knife profile (X1366V)? | | ||
+ | |||
+ | {{youtube> | ||
Check that the tangential knife is turned on in the settings. Alternatively, | Check that the tangential knife is turned on in the settings. Alternatively, |
faq.txt · Last modified: 2024/02/20 10:07 by ivan