++++ How to load G-code or DXF files into the software? | | ++++ How to load G-code or DXF files into the software? | | ||
+ | |||
+ | {{youtube> | ||
The files that you are attempting to load must be located in folders that are specified in the **Settings > Config > Preferences > Common** fields for **NC code folders**. If a folder that you would like to load your files from is missing, add it on a new line and press the Save Configuration button: | The files that you are attempting to load must be located in folders that are specified in the **Settings > Config > Preferences > Common** fields for **NC code folders**. If a folder that you would like to load your files from is missing, add it on a new line and press the Save Configuration button: | ||
Line 54: | Line 56: | ||
'' | '' | ||
+ | |||
+ | To load file from your USB drive, you can add the following folder to the NC code folders list: | ||
+ | |||
+ | ''/ | ||
The '' | The '' | ||
Line 241: | Line 247: | ||
++++ Why do ports turn on/off automatically when opening and closing the program? | | ++++ Why do ports turn on/off automatically when opening and closing the program? | | ||
+ | |||
+ | {{youtube> | ||
Check the _HANDLER_INIT and _HANDLER_EXIT Software PLCs for the starting and closing commands respectively (specifically, | Check the _HANDLER_INIT and _HANDLER_EXIT Software PLCs for the starting and closing commands respectively (specifically, | ||
Line 321: | Line 329: | ||
* Check that the reference voltage has been chosen correctly | * Check that the reference voltage has been chosen correctly | ||
{{hardware: | {{hardware: | ||
- | * In Settings > Config > Technology > THC, check that the Alarm Arc Voltage Difference and Alarm Arc Voltage Rise aren't set to a value that's too low - in cases where the reference and the measured voltage | + | * In Settings > Config > Technology > THC, check that the Alarm Arc Voltage Difference and Alarm Arc Voltage Rise aren't set to a value that's too low - in cases where the difference between |
{{: | {{: | ||
* Check that THC is enabled in the User Settings | * Check that THC is enabled in the User Settings |