Line 247: Line 247:
  
 The ''portset'' command activates a certain port (for example, //portset(3)// will activate output #3), while the ''portclr'' command clears the specified port (//portclr(3)// will turn off output #3). In order to disable these commands, either delete them from the relevant Software PLCs, or comment them out by putting two forward slashes in front of the commands. Don't forget to press the Save All and Build All buttons to make sure that the changes take effect.  The ''portset'' command activates a certain port (for example, //portset(3)// will activate output #3), while the ''portclr'' command clears the specified port (//portclr(3)// will turn off output #3). In order to disable these commands, either delete them from the relevant Software PLCs, or comment them out by putting two forward slashes in front of the commands. Don't forget to press the Save All and Build All buttons to make sure that the changes take effect. 
 +
 +++++
 +
 +++++ Why is the tool change macro M6 not working? |
 +
 +Check that the M6TXX tool change commands are accepted by the myCNC software (Settings > Config > G-codes settings > Tool Change M6TXX):
 +
 +{{::config-080-tool-change.png}}
  
 ++++ ++++
Line 313: Line 321:
   * Check that the reference voltage has been chosen correctly   * Check that the reference voltage has been chosen correctly
 {{hardware:thc:mycnc-thc-012.png}} {{hardware:thc:mycnc-thc-012.png}}
-  * In Settings > Config > Technology > THC, check that the Alarm Arc Voltage Difference and Alarm Arc Voltage Rise aren't set to a value that's too low - in cases where the reference and the measured voltage are too different, a small value of the Alarm Arc Voltage Difference will prevent the THC system from starting. Set the value to 1000 to temporarily disable this feature. +  * In Settings > Config > Technology > THC, check that the Alarm Arc Voltage Difference and Alarm Arc Voltage Rise aren't set to a value that's too low - in cases where the difference between reference and measured voltage is too great, a small value of the Alarm Arc Voltage Difference will prevent the THC system from starting. Set the value to 1000 to temporarily disable this feature. 
 {{:thc:thc-setup-008-arc-alarm.png}} {{:thc:thc-setup-008-arc-alarm.png}}
   * Check that THC is enabled in the User Settings   * Check that THC is enabled in the User Settings