Variable Name | Variable Address | Comments |
---|---|---|
GVAR_MODAL_G0_G3 | 4001 | Modal state of G00, G01, G02, G03, G33, G34 |
GVAR_MODAL_G96_G97 | 4002 | Modal state of G96, G97 |
GVAR_MODAL_G68_G69 | 4004 | Modal state of G68, G69 |
GVAR_MODAL_G98_G99 | 4005 | Modal state of G98, G99 |
GVAR_MODAL_G20_G21 | 4006 | Modal state of G20, G21 |
GVAR_MODAL_G40_G42 | 4007 | Modal state of G40, G41, G42 |
GVAR_MODAL_G25_G26 | 4008 | Modal state of G25, G26 |
GVAR_MODAL_G22_G23 | 4009 | Modal state of G22, G23 |
GVAR_MODAL_G80_G89 | 4010 | Modal state of G80 - G89 |
GVAR_MODAL_G66_G67 | 4012 | Modal state of G66, G67 |
GVAR_MODAL_G54_G59 | 4014 | Modal state of G54-G59 |
GVAR_MODAL_G17_G19 | 4016 | Modal state of G17-G19 |
GVAR_TOOL_1_X_CORRECTION | 4600 | +98 |
GVAR_TOOL_1_Z_CORRECTION | 4700 | +98 |
4800 | ||
5001 | (+8) program position at the end of current block | |
GVAR_CURRENT_MACHINE_POSITION | 5021 | (+8) Current position in Machine coordinates 5021 - Machine Position X 5022 - Machine Position Y 5023 - Machine Position Z 5024 - Machine Position A 5025 - Machine Position B 5026 - Machine Position C 5027 - Machine Position U 5028 - Machine Position V 5029 - Machine Position W |
GVAR_CURRENT_PROGRAM_POSITION | 5041 | (+8) Current position in Work coordinates 5041 - Work Position X 5042 - Work Position Y 5043 - Work Position Z 5044 - Work Position A 5045 - Work Position B 5046 - Work Position C 5047 - Work Position U 5048 - Work Position V 5049 - Work Position W |
GVAR_OFFSET_G38_PROBE | 5061 | |
GVAR_G38_PROBE_RESULT | 5070 | |
GVAR_OFFSET_G28 | 5161 | Machine coordinates for G28 Home Position 5161 - G28 X Position 5162 - G28 Y Position 5163 - G28 Z Position 5164 - G28 A Position 5165 - G28 B Position 5166 - G28 C Position 5167 - G28 U Position 5168 - G28 V Position 5169 - G28 W Position |
GVAR_OFFSET_G30 | 5181 | Machine coordinates for G30 Home Position 5181 - G30 X Position 5182 - G30 Y Position 5183 - G30 Z Position 5184 - G30 A Position 5185 - G30 B Position 5186 - G30 C Position 5187 - G30 U Position 5188 - G30 V Position 5189 - G30 W Position |
5211 | ||
GVAR_COORD_SYSTEM_NUMBER | 5220 | Register keeps Current Coordinates System number 1- G54, 2- G55, 3- G56, 4- G57, 5- G58, 6- G59, 7- G59.1, 8- G59.2, 9- G59.3 |
GVAR_OFFSET_G54_DATA | 5221 | (+8) Offsets between Machine and Work coordinates for Coordinates system #1 (G54) #5221 - G54 Offset X, #5222 - G54 Offset Y, #5223 - G54 Offset Z, #5224 - G54 Offset A, #5225 - G54 Offset B, #5226 - G54 Offset C, #5227 - G54 Offset U, #5228 - G54 Offset V, #5229 - G54 Offset W |
GVAR_OFFSET_G55_DATA | 5241 | (+8) Offsets between Machine and Work coordinates for Coordinates system #2 (G55) #5241 - G55 Offset X, #5242 - G55 Offset Y, #5243 - G55 Offset Z, #5244 - G55 Offset A, #5245 - G55 Offset B, #5246 - G55 Offset C, #5247 - G55 Offset U, #5248 - G55 Offset V, #5249 - G55 Offset W |
GVAR_OFFSET_G57_DATA | 5261 | (+8) Offsets between Machine and Work coordinates for Coordinates system #3 (G56) #5261 - G56 Offset X, #5262 - G56 Offset Y, #5263 - G56 Offset Z, #5264 - G56 Offset A, #5265 - G56 Offset B, #5266 - G56 Offset C, #5267 - G56 Offset U, #5268 - G56 Offset V, #5269 - G56 Offset W |
GVAR_OFFSET_G57_DATA | 5281 | (+8) Offsets between Machine and Work coordinates for Coordinates system #4 (G57) #5281 - G57 Offset X, #5282 - G57 Offset Y, #5283 - G57 Offset Z, #5284 - G57 Offset A, #5285 - G57 Offset B, #5286 - G57 Offset C, #5287 - G57 Offset U, #5288 - G57 Offset V, #5289 - G57 Offset W |
GVAR_OFFSET_G58_DATA | 5301 | (+8) Offsets between Machine and Work coordinates for Coordinates system #5 (G58) #5301 - G58 Offset X, #5302 - G58 Offset Y, #5303 - G58 Offset Z, #5304 - G58 Offset A, #5305 - G58 Offset B, #5306 - G58 Offset C, #5307 - G58 Offset U, #5308 - G58 Offset V, #5309 - G58 Offset W |
GVAR_OFFSET_G59_DATA | 5321 | (+8) Offsets between Machine and Work coordinates for Coordinates system #6 (G59) #5321 - G59 Offset X, #5322 - G59 Offset Y, #5323 - G59 Offset Z, #5924 - G59 Offset A, #5325 - G59 Offset B, #5326 - G59 Offset C, #5327 - G59 Offset U, #5328 - G59 Offset V, #5329 - G59 Offset W |
GVAR_OFFSET_G591_DATA | 5341 | (+8) Offsets between Machine and Work coordinates for Coordinates system #7 (G59.1) #5341 - G59.1 Offset X, #5342 - G59.1 Offset Y, #5343 - G59.1 Offset Z, #5344 - G59.1 Offset A, #5345 - G59.1 Offset B, #3426 - G59.1 Offset C, #5347 - G59.1 Offset U, #5348 - G59.1 Offset V, #5349 - G59.1 Offset W |
GVAR_OFFSET_G592_DATA | 5361 | (+8) Offsets between Machine and Work coordinates for Coordinates system #8 (G59.2) #5361 - G59.2 Offset X, #5362 - G59.2 Offset Y, #5363 - G59.2 Offset Z, #5364 - G59.2 Offset A, #5365 - G59.2 Offset B, #5366 - G59.2 Offset C, #5367 - G59.2 Offset U, #5368 - G59.2 Offset V, #5369 - G59.2 Offset W |
GVAR_OFFSET_G593_DATA | 5381 | (+8) Offsets between Machine and Work coordinates for Coordinates system #9 (G59.3) #5381 - G59.3 Offset X, #5382 - G59.3 Offset Y, #5383 - G59.3 Offset Z, #5384 - G59.3 Offset A, #5385 - G59.3 Offset B, #5386 - G59.3 Offset C, #5387 - G59.3 Offset U, #5388 - G59.3 Offset V, #5389 - G59.3 Offset W |
GVAR_CHECK_TOOL_MISMATCH | 5397 | |
GVAR_CHECK_TOOL_BREAKAGE | 5398 | A register contains Tool integrity flag. It's supposed a Tool integrity procedure will write “1” to this register is a Tool Breakage is detected. A “0” value is written while the broken tool is replaced. |
GVAR_OFFSET_TOOL_PARAMS | 5400 | |
GVAR_CURRENT_TOOL_NUMBER | 5400 | Current Tool Number is stored in this register |
GVAR_CURRENT_TOOL_OFFSET | 5401 | +8 for all axes |
GVAR_SCHEDULED_TOOL_NUMBER | 5409 | A Tool number, that going to be next in tool holder. ATC procedure uses both #5400 and #5409 registers to find where to put a current tool and where from to get the new one. |
GVAR_CURRENT_TOOL_DIAMETER | 5410 | The register keeps a diameter of the Current Tool. Register value is updated from Tool table when Current Tool number (#5400) is changed. |
GVAR_TOOL_FRONTANGLE | 5411 | A register is reserved for future implementation |
GVAR_TOOL_BACKANGLE | 5412 | A register is reserved for future implementation |
GVAR_TOOL_ORIENTATION | 5413 | A register is reserved for future implementation |
GVAR_TOOL_HOLDER_ORIENTATION | 5415 | A register is reserved for future implementation |
GVAR_SOFT_LIMITS_MIN | 5421 | (+8) Soft Limits Minimum Position 5421 - Soft Limit Minimum X Position 5422 - Soft Limit Minimum Y Position 5423 - Soft Limit Minimum Z Position 5424 - Soft Limit Minimum A Position 5425 - Soft Limit Minimum B Position 5426 - Soft Limit Minimum C Position 5427 - Soft Limit Minimum U Position 5428 - Soft Limit Minimum V Position 5429 - Soft Limit Minimum W Position |
GVAR_SOFT_LIMITS_MAX | 5431 | (+8) Soft Limits Maximum Position 5431 - Soft Limit Maximum X Position 5432 - Soft Limit Maximum Y Position 5433 - Soft Limit Maximum Z Position 5434 - Soft Limit Maximum A Position 5435 - Soft Limit Maximum B Position 5436 - Soft Limit Maximum C Position 5437 - Soft Limit Maximum U Position 5438 - Soft Limit Maximum V Position 5439 - Soft Limit Maximum W Position |
GVAR_OFFSET_G282 | 5441 | |
GVAR_HOME_AFTER_POSITION | 5451 | (+8) Registers contain values that used by Homing macros to initialize Machine Position after Homing done 5451 - Machine Position X after Homing 5452 - Machine Position Y after Homing 5453 - Machine Position Z after Homing 5454 - Machine Position A after Homing 5455 - Machine Position B after Homing 5456 - Machine Position C after Homing 5457 - Machine Position U after Homing 5458 - Machine Position V after Homing 5459 - Machine Position W after Homing |
GVAR_CURRENT_NUM_LINE | 5480 | Stop NC line |
GVAR_CURRENT_NUM_NC | 5460 | Stop NC line |
GVAR_CURRENT_NC_POSITION | 5461 | (+8) Registers keeps Toolpath Work coordinates when Job running was stopped (Paused). This registers are used by “Back to Path” procedure to return the tool on the toolpath position 5461 - Current NC Position X 5462 - Current NC Position Y 5463 - Current NC Position Z 5464 - Current NC Position A 5465 - Current NC Position B 5466 - Current NC Position C 5467 - Current NC Position U 5468 - Current NC Position V 5469 - Current NC Position W |
GVAR_TOOL_SENSOR_POSITION | 5471 | (+8) |
GVAR_SURFACE_SENSOR_WIDTH | 5490 | |
GVAR_PIERCE_HEIGHT | 5491 | |
GVAR_OFFSETZ_MANUAL | 5492 | |
GVAR_OFFSETZ_THC | 5493 | |
GVAR_SURFACE_SENSOR_NUMBER | 5494 | |
GVAR_SURFACE_SENSOR_TYPE | 5495 | |
GVAR_SHEET_THICKNESS | 5496 | |
GVAR_OFFSET_G283 | 5501 | |
GVAR_OFFSET_G284 | 5511 | +9 |
GVAR_END_SENSORS_IGNORE | 5521 | Writing “1” to this register will turn off Hardware Limit Sensors control temporarily. |
GVAR_JOG_STEP_SIZE | 5522 | |
GVAR_JOG_STEP_FLOAT | 5523 | |
GVAR_SPINDLE_SPEED | 5524 | Register represents given Spindle Speed. It's equal to “Default Spindle Speed” by default. If G-code program “S”-code with new spidnle speed settings executed, the value will be changed accordingly. |
GVAR_SOFT_LIMITS_IGNORE | 5525 | Writing “1” to this register will turn off Software Limits control temporarily. |
GVAR_M30_SCHEDULED_REWIND | 5526 | |
GVAR_SHOW_NCMESSAGE | 5527 | |
GVAR_DRAWING_MODE | 5528 | |
GVAR_SHOCK_SENSOR_IGNORE | 5529 | |
GVAR_STEP_PER_UNIT | 5530 | +6 |
| 5541 | (+8) Registers are obsolete since another address space is reserved to ge up to 20 parking coordinates |
| 5551 | (+8) Registers are obsolete since another address space is reserved to ge up to 20 parking coordinates |
| 5561 | (+8) Registers are obsolete since another address space is reserved to ge up to 20 parking coordinates |
| 5571 | (+8) Registers are obsolete since another address space is reserved to ge up to 20 parking coordinates |
| 5581 | (+8) Registers are obsolete since another address space is reserved to ge up to 20 parking coordinates |
| 5591 | (+8) Registers are obsolete since another address space is reserved to ge up to 20 parking coordinates |
GVAR_CURRENT_TOOLCHANGER_TYPE | 5600 | |
GVAR_TOOLCHANGER_UNLOAD_OFFSET | 5601 | +8 |
GVAR_TOOLCHANGER_BLOW_OFF_OFFSET | 5610 | +8 |
GVAR_MYDEV_MSG_COUNTER | 5630 | +64 till 5694 |
GVAR_TECHNOLOGY_CFG | 5701 | 0- flexible; 1- plasma; 2- gas; 3- mill; 4- lathe; 5- laser engraving enum{ TECH5701_FLEX=0, TECH5701_PLASMA, //1 TECH5701_GAS, //2 TECH5701_MILL, //3 TECH5701_LATHE, //4 TECH5701_LASER_ENG //5 }; |
GVAR_THC_ENABLE | 5702 | 0- disable; 1- enable |
GVAR_IHC_ENABLE | 5703 | 0- disable; 1- enable |
| 5705 | ET5 SLOW PID: 0- disable; 1- enable |
GVAR_CV_MODE | 5710 | |
GVAR_CV_TOLERANCE | 5711 | |
GVAR_SOFT_LIMITS_CHECKER | 5714 | |
GVAR_LATHE_GEARS | 5715 | |
GVAR_MODE_SINGLE_BLOCK | 5720 | |
GVAR_POSITION_STORED | 5900 | |
GVAR_CURRENT_MOTION_CODE | 6060 | |
GVAR_CURRENT_MOTION_WORK_PTR | 6061 | Motion controller work command pointer |
GVAR_CURRENT_MOTION_LAST_PTR | 6062 | Motion controller work command pointer |
GVAR_CURRENT_NC_LINE | 6063 | Current NC line number |
GVAR_TOTAL_NC_LINES | 6064 | |
GVAR_SYSTEM_JOB_RUN | 6065 | |
GVAR_OIL_LENGTH_COUNTER | 6080 | |
GVAR_OIL_REVERSE_COUNTER | 6081 | |
GVAR_SOFT_LIMITS_CONTROL | 6083 | |
GVAR_TOOLCHANGER_POSITION | 6101 | +8 |
GVAR_TOOLCHANGER_NEXT_POSITION | 6111 | +6 |
GVAR_TOOLPOT_1_POSITION | 6121 | +6 |
GVAR_TOOLPOT_2_POSITION | 6131 | +6 |
GVAR_TOOLPOT_3_POSITION | 6141 | +6 |
GVAR_TOOLPOT_4_POSITION | 6151 | +6 |
GVAR_TOOLPOT_5_POSITION | 6161 | +6 |
GVAR_TOOLPOT_6_POSITION | 6171 | +6 |
GVAR_TOOLPOT_7_POSITION | 6181 | +6 |
GVAR_TOOLPOT_8_POSITION | 6191 | +6 |
GVAR_TOOLPOT_9_POSITION | 6201 | +6 |
GVAR_TOOLPOT_10_POSITION | 6211 | +6 |
GVAR_TOOLPOT_11_POSITION | 6221 | +6 |
GVAR_TOOLPOT_12_POSITION | 6231 | +6 |
GVAR_TOOLPOT_13_POSITION | 6241 | +6 |
GVAR_TOOLPOT_14_POSITION | 6251 | +6 |
GVAR_TOOLPOT_15_POSITION | 6261 | +6 |
GVAR_TOOLPOT_16_POSITION | 6271 | +6 |
GVAR_TOOL_CHANGE_SPEED | 6970 | |
GVAR_TAGENTKNIFE_ANGLE | 7001 | |
GVAR_TAGENTKNIFE_POSITION | ||
GVAR_FEEDRATE_UNIT | 7003 | |
GVAR_ROTATERATE_UNIT | 7004 | |
GVAR_TANGENTKNIFE_ENABLE | 7005 | Register represents Automatic Tangential Knife control. If the register value is “0”, tangential control is disabled. If the register value is “1”, tangential knife control is enabled |
GVAR_PLC_MOVE_PROCESS | 7006 | |
GVAR_THC_PWMSPEED | 7009 | |
GVAR_THC_ARC_VOLTAGE | 7010 | |
GVAR_THC_ARC_VOLTAGE_REF | 7011 | |
GVAR_THC_ARC_VOLTAGE_ADJ | 7012 | |
GVAR_SAFE_HEIGHT (GVAR_TOOL_LIFT) | 7020 | Height value for safe XY motion. |
GVAR_CREEP_SPEED | 7021 | Safe speed while motion down to path position. |
GVAR_FEED_SPEED | 7030 | Feed Speed +9 |
GVAR_FEED_SPEED_X | 7030 | Feed Speed_X |
GVAR_RAPID_SPEED | 7040 | +9 |
GVAR_RAPID_SPEED_X | 7041 | Rapid Speed_X |
GVAR_JOG_SPEED | 7050 | +9 |
GVAR_JOG_SPEED_X | 7050 | Jog Speed_X |
GVAR_MARKING_SPEED | 7060 | +9 |
GVAR_JOG_STEP_UNLIMITED | 7070 | the value is “1” if Current Jog Mode is “Unlimited”, otherwize is “0” (integer) |
GVAR_JOG_LOCKED | 7071 | the value is “1” if Jogging is Locked, otherwize is “0” (integer) |
GVAR_MOTION_OVERSPEED | 7072 | |
GVAR_SPINDLE_OVERSPEED | 7073 | Register represents Spindle Overrate percentage. Actual Spindle speed will be Actual_Speed=Default_Speed * Spindle_Overspeed/100 Default Spindle Speed defined by “Default Spindle Speed” variable and can be chaned in G-code program with S-code. |
GVAR_JOG_OVERSPEED | 7074 | |
GVAR_PROBE_SENSOR_DIAMETER | 7075 | |
GVAR_PROBE_SENSOR_XOFFSET | 7076 | |
GVAR_PROBE_SENSOR_YOFFSET | 7077 | |
GVAR_MOTION_OVERSPEED_G0 | 7079 | |
GVAR_PLC_MOVE_SPEED | 7080 | |
GVAR_PLC_MOVE_ACCELERATION | 7081 | |
GVAR_PLC_RESET_COORDINATES | 7082 | |
GVAR_CAMERA_READY | 7090 | |
GVAR_MULTIDEV_MASK | 7100 | |
GVAR_MULTIDEV_ENABLE1 | 7101 | |
GVAR_MULTIDEV_ENABLE2 | 7102 | |
GVAR_MULTIDEV_ENABLE3 | 7103 | |
GVAR_MULTIDEV_ENABLE4 | 7104 | |
GVAR_MULTIDEV_ENABLE5 | 7105 | |
GVAR_MULTIDEV_ENABLE6 | 7106 | |
GVAR_MULTIDEV_ENABLE7 | 7107 | |
GVAR_MULTIDEV_ENABLE8 | 7108 | |
GVAR_MULTIDEV_ENABLE9 | 7109 | |
GVAR_MULTIDEV_ENABLE10 | 7110 | |
GVAR_MULTIDEV_ENABLE11 | 7111 | |
GVAR_MULTIDEV_ENABLE12 | 7112 | |
GVAR_MULTIDEV_ENABLE13 | 7113 | |
GVAR_MULTIDEV_ENABLE14 | 7114 | |
GVAR_MULTIDEV_ENABLE15 | 7115 | |
GVAR_MULTIDEV_ENABLE16 | 7116 | |
GVAR_MULTIDEV_ENABLE32 | 7132 | reserved up to 32 devices |
GVAR_MD_MASTER_MOTION_CODE | 7140 | master |
GVAR_M1_CONDITIONAL_STOP | 7150 | |
GVAR_LATHE_THREAD_PULLOUT | 7154 | |
GVAR_SPINDLE_ORIENTATION | 7155 | |
GVAR_PLASMA_PROCESS_CURRENT | 7156 | |
GVAR_ALIGN_CHECK | 7170 | |
GVAR_HW_INPUTS0 | 7180 | |
GVAR_HW_INPUTS1 | 7181 | |
GVAR_HW_INPUTS2 | 7182 | |
GVAR_HW_INPUTS3 | 7183 | |
GVAR_HW_OUTPUTS0 | 7184 | |
GVAR_HW_OUTPUTS1 | 7185 | |
GVAR_HW_OUTPUTS2 | 7186 | |
GVAR_HW_OUTPUTS3 | 7187 | |
GVAR_HW_INPUTS4 | 7188 | |
GVAR_HW_INPUTS5 | 7189 | |
GVAR_HW_INPUTS6 | 7190 | |
GVAR_HW_INPUTS7 | 7191 | |
GVAR_HW_OUTPUTS4 | 7192 | |
GVAR_HW_OUTPUTS5 | 7193 | |
GVAR_HW_OUTPUTS6 | 7194 | |
GVAR_HW_OUTPUTS7 | 7195 | |
GVAR_HW_ADC0 | 7196 | |
GVAR_HW_ADC1 | 7197 | |
GVAR_HW_ADC2 | 7198 | |
GVAR_HW_ADC3 | 7199 | |
GVAR_HW_ADC4 | 7200 | |
GVAR_HW_ADC5 | 7201 | |
GVAR_HW_ADC6 | 7202 | |
GVAR_HW_ADC7 | 7203 | |
GVAR_HW_INP_TCOUNT0 | 7206 | |
GVAR_HW_INP_TCOUNT1 | 7207 | |
GVAR_HW_INP_TCOUNT2 | 7208 | |
GVAR_HW_INP_TCOUNT3 | 7209 | |
GVAR_PARKING_LAST | 7210 | |
GVAR_RTCP_DEBUG_X | 7211 | RTCP correction data for X axis is stored in this register for debug purpose. This register is read-only |
GVAR_RTCP_DEBUG_Y | 7212 | RTCP correction data for Y axis is stored in this register for debug purpose. This register is read-only |
GVAR_RTCP_DEBUG_Z | 7213 | RTCP correction data for Z axis is stored in this register for debug purpose. This register is read-only |
GVAR_RTCP_SHOULDER | 7215 | Shoulder Length (in units) for RTCP correction calculation. |
GVAR_HEAD1_ENABLE | 7221 | |
GVAR_HEAD2_ENABLE | 7222 | |
GVAR_HEAD3_ENABLE | 7223 | |
GVAR_HEAD4_ENABLE | 7224 | |
GVAR_HCONTROL_VREF | 7229 | |
GVAR_PLC_USER_DATA | 7230 | (+32) |
GVAR_PLC_USER_DATA_LAST | 7261 | |
GVAR_HW_DAC0 | 7270 | |
GVAR_HW_DAC1 | 7271 | |
GVAR_HW_DAC2 | 7272 | |
GVAR_HW_DAC3 | 7273 | |
GVAR_HW_DAC4 | 7274 | |
GVAR_HW_DAC5 | 7275 | |
GVAR_HW_DAC6 | 7276 | |
GVAR_HW_DAC7 | 7277 | |
GVAR_HW_PWM0 | 7278 | |
GVAR_HW_PWM1 | 7279 | |
GVAR_HW_PWM2 | 7280 | |
GVAR_HW_PWM3 | 7281 | |
GVAR_HW_PWM4 | 7282 | |
GVAR_HW_PWM5 | 7283 | |
GVAR_HW_PWM6 | 7284 | |
GVAR_HW_PWM7 | 7285 | |
GVAR_GOTO_PROGRAMMING | 7290 | |
GVAR_GOTO_POSITION | 7291 | +16 |
GVAR_REFERENCE_POSITION | 7311 | +16 |
GVAR_PRG_RECT_P | 7330 | +16 |
GVAR_PRG_RECT_M | 7350 | +16 |
GVAR_PLC_SPINDLE_STATE | 7370 | |
GVAR_PLC_SPINDLE_SPEED | 7371 | |
GVAR_PLC_COOLANT_STATE | 7372 | |
GVAR_PLC_MIST_STATE | 7373 | |
GVAR_JOG_STEP_SIZE | 5522 | prepresents current jog step size (double) |
GVAR_JOG_STEP_0_0001 | 7381 | the value is “1” if Current Jog Step Size is “0.0001”, otherwize is “0” (integer) |
GVAR_JOG_STEP_0_001 | 7382 | the value is “1” if Current Jog Step Size is “0.001”, otherwize is “0” (integer) |
GVAR_JOG_STEP_0_01 | 7383 | the value is “1” if Current Jog Step Size is “0.01”, otherwize is “0” (integer) |
GVAR_JOG_STEP_0_1 | 7384 | the value is “1” if Current Jog Step Size is “0.1”, otherwize is “0” (integer) |
GVAR_JOG_STEP_1_0 | 7385 | the value is “1” if Current Jog Step Size is “1.0”, otherwize is “0” (integer) |
GVAR_JOG_STEP_10 | 7386 | the value is “1” if Current Jog Step Size is “10”, otherwize is “0” (integer) |
GVAR_SYSTEM_CONFIGURED | 7390 | |
GVAR_HOMING_X_RESET | 7391 | The register value is used as a flag that Homing X needed. The value is automatically set to “1” is - CNC control software just loaded - Emergency button pressed - X Servo Driver not ready event received The register can be used for either Mandatory Homing Handler procedure or just to display information about possible X position lost |
GVAR_HOMING_Y_RESET | 7392 | The register value is used as a flag that Homing Y needed. The value is automatically set to “1” is - CNC control software just loaded - Emergency button pressed - Y Servo Driver not ready event received The register can be used either for Mandatory Homing Handler procedure or just to display information about possible Y position lost |
GVAR_HOMING_Z_RESET | 7393 | The register value is used as a flag that Homing Z needed. The value is automatically set to “1” is - CNC control software just loaded - Emergency button pressed - Z Servo Driver not ready event received The register can be used for either Mandatory Homing Handler procedure or just to display information about possible Z position lost |
GVAR_HOMING_A_RESET | 7394 | The register value is used as a flag that Homing A needed. The value is automatically set to “1” is - CNC control software just loaded - Emergency button pressed - A Servo Driver not ready event received The register can be used for either Mandatory Homing Handler procedure or just to display information about possible A position lost |
GVAR_HOMING_B_RESET | 7395 | The register value is used as a flag that Homing B needed. The value is automatically set to “1” is - CNC control software just loaded - Emergency button pressed - B Servo Driver not ready event received The register can be used for either Mandatory Homing Handler procedure or just to display information about possible B position lost |
GVAR_HOMING_C_RESET | 7396 | The register value is used as a flag that Homing C needed. The value is automatically set to “1” is - CNC control software just loaded - Emergency button pressed - C Servo Driver not ready event received The register can be used for either Mandatory Homing Handler procedure or just to display information about possible C position lost |
GVAR_PRG_EXTREMA_P | 7400 | +16 |
GVAR_PRG_EXTREMA_M | 7420 | +16 |
GVAR_CURRENT_FEEDRATE | 7440 | |
GVAR_TUBE_DIAMETER | 7450 | |
GVAR_HT_CURRENT_SETPOINT GVAR_PLASMA_PROCESS_CURRENT | ||
GVAR_HT_PLASMA_PREFLOW | 7461 | |
GVAR_HT_PLASMA_CUTFLOW | 7462 | |
GVAR_HT_SHIELD_PREFLOW | 7463 | |
GVAR_HT_SHIELD_CUTFLOW | 7464 | |
GVAR_HT_PLASMA_GAS_TYPE | 7465 | |
GVAR_HT_SHIELD_GAS_TYPE | 7466 | |
GVAR_HT_GAS_MIXING_SETPOINT | 7467 | |
GVAR_HT_SYSTEM_ERROR | 7468 | |
GVAR_HT_SYSTEM_STATUS | 7469 | |
GVAR_HT_PUMP_CONTROL | 7470 | |
GVAR_HT_FIRMWARE_VERSION | 7471 | |
GVAR_HT_TEST_CUTFLOW_GASES | 7472 | |
GVAR_HT_TEST_PREFLOW_GASES | 7473 | |
GVAR_HT_LINE_VOLTAGE | 7474 | |
GVAR_HT_CHOPPER_CURRENT | 7475 | |
GVAR_HT_WORK_LEAD_CURRENT | 7476 | |
GVAR_HT_CHOPPER_TEMPERATURE | 7477 | |
GVAR_HT_TRANS_TEMPERATURE | 7478 | |
GVAR_HT_GAS_PRESSURE | 7479 | |
GVAR_HT_COOLANT_FLOW_RATE | 7480 | |
GVAR_HT_CURRENT_ACTUAL | 7481 | |
GVAR_OXYFUEL_PREHEAT_COUNTDOUN | 7490 | |
GVAR_OXYFUEL_PREHEAT_COUNTDOUN_V2 | 7491 | |
GVAR_PROBE_SENSOR_CORRECTION_XMINUS | 7501 | |
GVAR_PROBE_SENSOR_CORRECTION_XPLUS | 7502 | |
GVAR_PROBE_SENSOR_CORRECTION_YMINUS | 7503 | |
GVAR_PROBE_SENSOR_CORRECTION_YPLUS | 7504 | |
GVAR_PROBE_SENSOR_CORRECTION_CENTERX | 7505 | |
GVAR_PROBE_SENSOR_CORRECTION_CENTERY | 7506 | |
GVAR_CUTTING_FROM_EDGE | 7520 | |
GVAR_MIST_PULSE_WIDTH | 7521 | NS-CNC Pulse Mist Mode |
GVAR_MIST_PULSE_PAUSE | 7522 | |
GVAR_GANTRY_CORRECTION | 7525 | |
GVAR_DRAWING_FAST | 7530 | |
GVAR_SHOW2D_AXISA_RADIUS | 7540 | |
GVAR_ASSIGN_TOOL_OFFSET_X | 7515 | |
GVAR_ASSIGN_TOOL_OFFSET_Z | 7517 | |
GVAR_LATHE_TOOL_LENGTH_CORRECTION_X | 7511 | |
GVAR_LATHE_TOOL_LENGTH_CORRECTION_Z | 7513 | |
GVAR_LATHE_TOOL_OFFSET_CORRECTION_X | 7514 | |
GVAR_SAW_WIDTH | 7550 | |
GVAR_SAW_POSTION_START | 7551 | |
GVAR_SAW_POSTION_END | 7552 | |
GVAR_SAW_SLOT_L | 7553 | |
GVAR_SAW_SLOT_L1 | 7554 | |
GVAR_SAW_GROOVE_L | 7555 | |
GVAR_SAW_GROOVE_T | 7556 | |
GVAR_SAW_Z_SAFE | 7557 | |
GVAR_SAW_Z_WORK | 7558 | |
GVAR_SAW_CUT_WIDTH | 7559 | |
GVAR_SAW_DIAMETER | 7560 | |
THC Control variables | ||
THC #0 | ||
GVAR_THC0_CONTROL | 7570 | THC API |
GVAR_THC0_INPUT | 7571 | THC API |
GVAR_THC0_VREF | 7572 | THC API |
GVAR_THC0_OFFSETZ | 7573 | THC API |
GVAR_THC0_ENABLED | 7574 | THC API |
THC #1 | ||
GVAR_THC1_CONTROL | 7575 | THC API |
GVAR_THC1_INPUT | 7576 | THC API |
GVAR_THC1_VREF | 7577 | THC API |
GVAR_THC1_OFFSETZ | 7578 | THC API |
GVAR_THC1_ENABLED | 7579 | THC API |
THC # | ||
GVAR_THC2_CONTROL | 7580 | THC API |
GVAR_THC2_INPUT | 7581 | THC API |
GVAR_THC2_VREF | 7582 | THC API |
GVAR_THC2_OFFSETZ | 7583 | THC API |
GVAR_THC2_ENABLED | 7584 | THC API |
THC #3 | ||
GVAR_THC3_CONTROL | 7585 | THC API |
GVAR_THC3_INPUT | 7586 | THC API |
GVAR_THC3_VREF | 7587 | THC API |
GVAR_THC3_OFFSETZ | 7588 | THC API |
GVAR_THC3_ENABLED | 7589 | THC API |
GVAR_KNIFE_FLAG | 7587 | PLC/Software controlled variable. Tool change PLC procedure writes “1” to the register when Tool number changed to Tangential Knife Tool, otherwise writes “0”. |
Cutchart variables | ||
GVAR_CUTPROCESS_ID | 7600 | |
GVAR_CUTPROCESS_KERF | 7601 | |
GVAR_CUTPROCESS_MATERIAL_THICKNESS | 7602 | |
GVAR_CUTPROCESS_TIME_PREHEAT | 7603 | |
GVAR_CUTPROCESS_TIME_SOFT_OXY_START | 7604 | |
GVAR_CUTPROCESS_CUTSPEED | 7605 | |
GVAR_CUTPROCESS_AGC_IGNITION_FUEL | 7610 | |
GVAR_CUTPROCESS_AGC_IGNITION_OXY_HEAT | 7611 | |
GVAR_CUTPROCESS_AGC_PREHEAT_FUEL | 7612 | |
GVAR_CUTPROCESS_AGC_PIERCE_FUEL | 7613 | |
GVAR_CUTPROCESS_AGC_PIERCE_OXY_CUT | 7614 | |
GVAR_CUTPROCESS_AGC_PIERCE_OXY_HEAT | 7615 | |
GVAR_CUTPROCESS_AGC_CUTTING_FUEL | 7616 | |
GVAR_CUTPROCESS_AGC_CUTTING_OXY_HEAT | 7617 | |
GVAR_CUTPROCESS_AGC_CUTTING_OXY_CUT | 7618 | |
GVAR_CUTPROCESS_AGC_PILOT_FUEL | 7619 | |
GVAR_CUTPROCESS_AGC_PILOT_OXY_HEAT | 7620 | |
GVAR_CUTPROCESS_GAS_SELECT1 | 7621 | |
GVAR_CUTPROCESS_GAS_SELECT2 | 7622 | |
GVAR_CUTPROCESS_SHIELD_RETAINING_CAP | 7630 | |
GVAR_CUTPROCESS_SHIELD | 7631 | |
GVAR_CUTPROCESS_NOZZLE_RETAINING_CAP | 7632 | |
GVAR_CUTPROCESS_NOZZLE | 7633 | |
GVAR_CUTPROCESS_SWIRL_RING | 7634 | |
GVAR_CUTPROCESS_ELECTRODE | 7635 | |
GVAR_CUTPROCESS_WATER_TUBE | 7636 | |
GVAR_CUTPROCESS_HC_PIERCE_DELAY | 7640 | |
GVAR_CUTPROCESS_HC_IGNITION_HEIGHT | 7641 | |
GVAR_CUTPROCESS_HC_PIERCE_HEIGHT | 7642 | |
GVAR_CUTPROCESS_HC_CUT_HEIGHT | 7643 | |
GVAR_CUTPROCESS_HC_CONTROL_DELAY | 7644 | |
GVAR_CUTPROCESS_HC_ARC_VOLTAGE | 7645 | |
GVAR_CUTPROCESS_HC_PIERCE_HEIGHT_FACTOR | 7646 | |
GVAR_CUTPROCESS_CREEP_TIME | 7650 | |
GVAR_CUTPROCESS_CREEP_SPEED | 7651 | |
GVAR_CUTPROCESS_MIX_GAS1 | 7652 | |
GVAR_CUTPROCESS_MIX_GAS2 | 7653 | |
Plasma Automatic Gas Console | ||
GVAR_CUTPROCESS_AGC_PLASMA_PREFLOW | 7660 | |
GVAR_CUTPROCESS_AGC_SHIELD_PREFLOW | 7661 | |
GVAR_CUTPROCESS_AGC_PLASMA_CUTEFLOW | 7662 | |
GVAR_CUTPROCESS_AGC_SHIELD_CUTEFLOW | 7663 | |
Plasma Manual Gas Console | ||
GVAR_CUTPROCESS_MGC_PLASMA_PREFLOW | 7670 | |
GVAR_CUTPROCESS_MGC_SHIELD_PREFLOW | 7671 | |
GVAR_CUTPROCESS_MGC_PLASMA_CUTEFLOW | 7672 | |
GVAR_CUTPROCESS_MGC_SHIELD_CUTEFLOW | 7673 | |
GVAR_CUTPROCESS_SET_PROCESS_CURRENT | 7675 | |
GVAR_CUTPROCESS_SET_ARC_CURRENT | 7676 | |
GVAR_CUTPROCESS_CORNER_REDUCTION | 7677 | |
GVAR_CUTPROCESS_TORCH_TYPE | 7680 | |
GVAR_CUTPROCESS_MATERIAL_TYPE | 7681 | |
GVAR_CUTPROCESS_SPECIFIC_MATERIAL | 7682 | |
GVAR_CUTPROCESS_PLASMA_SHIELD_GASES | 7683 | |
GVAR_CUTPROCESS_PROCESS | 7684 | |
GVAR_CUTPROCESS_VENDOR | 7685 | |
GVAR_CUTPROCESS_TECHNOLOGY | 7686 | |
GVAR_CUTPROCESS_REVISION | 7687 | |
Encoders | ||
GVAR_ET5_ENCODER | 9000 | (+16) Registers represent Encoder values. Writing to this registers does not affect anything. Selected channel Current Encoder value will be returned when reading these registers. Reading these registers from the controller Hardware PLC will return actual Encoder value. Encoder values in the software are updated about every 128ms. This delay should be counted when using Encoder values from the Software PLC. 9000 - Encoder #0 value 9001 - Encoder #1 value 9002 - Encoder #2 value 9003 - Encoder #3 value 9004 - Encoder #4 value 9005 - Encoder #5 value 9006 - Encoder #6 value 9007 - Encoder #7 value |
GVAR_ET5_EXPOSITION | 9016 | (+16) Registers represent Motor PID Following Error (a difference between commanded and sensed position). Writing to this registers does not affect anything. A Following Error of Selected PID will be returned when reading these registers. Reading these registers from the controller Hardware PLC will return actual value of the Following Error. Following Error values in the software are updated about every 128ms. This delay should be counted when using the registers in the Software PLC. 9016 - Motor channel #0 PID Following Error 9017 - Motor channel #1 PID Following Error 9018 - Motor channel #2 PID Following Error 9019 - Motor channel #3 PID Following Error 9020 - Motor channel #4 PID Following Error 9021 - Motor channel #5 PID Following Error 9022 - Motor channel #6 PID Following Error 9023 - Motor channel #7 PID Following Error Examples FERROR implementation |
GVAR_ET5_ENCODER_Z | 9032 | +16 |
GVAR_ET5_ENCODER_WZ | 9048 | +16 |
GVAR_ENCODER_Z_EVENT | 9070 | |
GVAR_POPUP_MESSAGE | 9100 | +16 |
GVAR_SERVO_PID_ON | 60000 | |
GVAR_SERVO_PID_OFF | 60001 | |
Modbus devices API | ||
GVAR_MODBUS_SET_ID | 60010 | Value written to this registed is used as Modbus ID of device to communicate with |
GVAR_MODBUS_SET_PROTOCOL | 60011 | Writing to this register change Modbus protocol. "0" - Modbus/RTU, "1" - Modbus/ASCII |
GVAR_MODBUS_SET_SPEED | 60012 | Writing to this register will change RS485/Modbus speed. Available speeds are 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 |
GVAR_MODBUS_SET_CONNECTION | 60013 | Change UART connection parameters: number of bits (8 or 7), parity (none, odd, even), number of stop bits (1, 2). Data comes in 3 low nibbles. The lowest is stop bits, then parity, then number of bits. Example: 0x801=8,N,1 0x712=7,O,2 0x822=8,E,2 |
GVAR_MODBUS_SET_VALUE | 60019 | Writing to register will latch the value in shadow register |
GVAR_MODBUS_SET_ADDRESS | 60020 | Writing to register will latch Address to read in shadow register |
GVAR_MODBUS_WRITE | 60030 | Writing to register will send value from shadow register to Modbus devive to address given in written value |
GVAR_MODBUS_READ | 60031 | Read from this register will send read inquiry to Modbus device (PLC controller will be in till Regiter value received from Modbus device). Writing to this register will send ready inquiry to Modbus device. The value written is used as Register address to read |