PLC Predefined Procedures
Most of PLC procedure names represent miscellaneous code. However there are a few reserved PLC names used as a standard event handlers.
Table. List of reserved PLC Procedures
PLC name | PLC description |
---|---|
EST | Emergency Stop Handler - procedure executed if Emergency Stop Button pressed. Emergency Stop Input is General purpose binary input assigned as Emergency in Alarms configuration dialog |
OFF | OFF moving procedure executed when Stop button pressed. Procedure may contain Stop Handler - stop motion program, clear motion buffer, lift tool to safe height, Off spindle (plasma power source, laser, gas cutting or so) |
SPN | Spindle Speed Control - Procedure executed if on-screen Spindle button pressed (Spindle speed +, -, set) or single “S” code executed when g-code program running |
TRIG01 - TRIG08 | Trigger #1-#8 Activated Handler procedures. Procedure executed when if corresponding trigger activated. Trigger is General purpose input defined in Triggers configuration dialog and activated in PLC procedure. |